Hz

Maximum Stroboscopic Flashes:

Flash
output

Wireless Flash Shooting: Radio (2.4G) Transmission

● 

You can set up five slave groups for TTL autoflash shooting.

  With TTL autoflash, you can easily create various lighting effects.

● Any flash settings for the slave units(auto flash, manual flash and 

stroboscopic  flash)  on  the  master  flash  in  TTL  mode  will  be 

automatically sent to the slave units. So the only thing you need to 

do  is  to  set  the  master  unit  for  each  slave  group  without  any 

operation for the slave units at all during the shooting.

● This flash can work in TTL /M /Multi/ OFF flash modes when set

  as a master unit.

Note:

● Even with multiple slave units, the X series flash trigger can 

control all of them via wireless.

● In this user manual, “master unit” refers to the camera flash 

on a camera and “slave unit” will be controlled by the 

master unit.

1/4

1/8

1/16

1/32

1/64

1/128

1/256

10

2

4

8

20

50

70

70

20-50

2

4

8

16

30

40

40

60-100

2

4

8

12

20

40

40

Positioning and Operation Range

 (Example of wireless flash 

shooting)

● 

Autoflash Shooting with One Slave Unit

● Use the supplied mini stand to position the slave unit.

● Before shooting, perform a test flash and test shooting.

● The transmission distance might be shorter depending on 

the conditions such as positioning of slave units, the 

surrounding environment and whether conditions.

Transmission distance is about 100m.

● 

Auto Shooting with Two Slave Groups

● 

Auto Shooting with Three Slave Groups

You can divide the slave units into two or three groups and perform 

TTL autoflash while changing the flash ratio (factor). In addition, you 

can set and shoot with a different flash mode for each firing group, 

for up to 5 groups.

Wireless Multiple Flash Shooting

A

B

A

B

C

-  43  -

-  44  -

1/4

1/8

1/16

1/32

1/64

1/128

1/256

1

8

14

30

60

90

100

100

2

6

14

30

60

90

100

100

3

4

12

30

60

90

100

100

4

3

10

20

50

80

100

100

5

3

8

20

50

80

100

100

6-7

2

6

20

40

70

90

90

8-9

2

5

10

30

60

80

80

Flash
output

Hz

Summary of Contents for V1-P

Page 1: ...oduct Please read this user manual carefully in order to ensure your safety and the proper operation of this product Keep for future reference 705 V1P000 00 GODOX Photo Equipment Co Ltd Made In China...

Page 2: ...damaged Turn off the flash unit immediately in the event of malfunction Thank you for purchasing this product This V1P camera flash applies to PENTAX series cameras and is compatible with TTL autofla...

Page 3: ...lash Multi Wireless Flash Shooting with Manual Flash Other Applications Sync Triggering Modeling Flash Auto Focus Assist Beam Bounce Flash ZOOM Setting the Flash Coverage Low Battery Indicator C Fn Se...

Page 4: ...4 such as and M A B C change according to settings status When a button or dial is operated the LCD panel illuminated M Manual flash Manual flash output 3 Multi Flash Multi Stroboscopic flash Number o...

Page 5: ...ansmission As a Slave Unit What s in the Box of V1P Kit 1 Flash Unit 2 Lithium Battery 3 USB Battery Charger 4 USB Line 5 Charger 6 Mini Stand 7 Protection Case 8 Instruction Manual Separately Sold Ac...

Page 6: ...sign 2on the battery pack insert it into the compartment until a white knob locks the battery with a click sound Battery Level Indication Make sure the battery pack is securely loaded in the flash Ch...

Page 7: ...mount 0 3 means 1 3 step 0 7 means 2 3 step To cancel the flash exposure compensation set the amount to 0 Press Set Button again to 3 confirm the setting Press Function Button 2 1Press the button The...

Page 8: ...g subject in a single photograph You can set the firing frequency number of flashes per sec expressed as Hz the number of flashes and the flash output Press MODE button so 1that is displayed Calculati...

Page 9: ...4 1 128 1 256 10 2 4 8 20 50 70 70 20 50 2 4 8 16 30 40 40 60 100 2 4 8 12 20 40 40 Positioning and Operation Range Example of wireless flash shooting Autoflash Shooting with One Slave Unit Use the su...

Page 10: ...confirm 4 Wireless ID Settings Change the wireless channels and wireless ID to avoid interference for it can only be triggered after the wireless IDs and channels of the master unit and the slave unit...

Page 11: ...ith a single slave unit Any flash group can be set A B C D E When the number of slave units is increased and the master unit flash firing is ON automatic control is implemented to make all groups of f...

Page 12: ...he flash will be fired synchronously with the camera shutter Modeling Flash If the camera has a depth of field preview button pressing it will fire the flash continuously for 1 second This is called m...

Page 13: ...iately 7 120 330 C Fn Setting Custom Functions The following table lists the available and unavailable custom functions of this flash m ft BEEP LIGHT LCD ZOOM ID m ft ON OFF 12sec OFF ON 3 3 APS 135 O...

Page 14: ...re are some errors occurred during the upgrading process Please using the correct firmware upgrade method Prompts on LCD Panel E1 E2 E3 E9 Technical Data V1P PENTAX cameras TTL autoflash 76Ws 28 to 10...

Page 15: ...ween 28 and 105mm or 19 to 69mm which fits medium format cameras Firmware Upgrade The USB port is a Type C USB socket Type C USB connection line is applicable As the firmware upgrade needs the support...

Page 16: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installatio...

Reviews: