electrical code requirements that separately derived AC sources (such as 
inverters and generators) have their neutral tied to ground in the same way that 
the neutral conductor from the utility line is tied to ground at AC breaker panel. 
 

Caution! 

The negative DC input of the power inverter is connected to the chassis. 
Do not install the power inverter in a positive ground DC system. A 
positive ground DC system has the positive terminal of the battery 
connected to the chassis of the vehicle or to the grounding point. 
 

Warning! 

Do not operate the power inverter without connecting it to ground. 
Electrical shock hazard may result. 

 

5.0 Operation 

To operate the power inverter, turn it on using the ON/OFF switch on the front 
panel. The power inverter is now ready to deliver AC power to your loads. If you 
are operating several loads from the power inverter, turn them on separately after 
the inverter has been turned on. This will ensure that the power inverter does not 
have to deliver the starting-currents for all the loads at once. 
 

5.1 Operating On/Off Switch 

The ON/OFF switch turns the control circuit in the power inverter ON and OFF. It 
does not disconnect power from the power inverter. When the switch is in the 
OFF position, the power inverter draws no current from the battery. When the 
switch is in the ON position but with no load, the power inverter draws less than 
1.65 A / normal, 0.07 A / saving mode (12 V version) from the battery. 
 

5.2 Battery voltage indicator 

The battery voltage bar graph on the SW1500 indicates the voltage at the input 
terminals of the power inverter. At low input current, this voltage is very close to 
the battery voltage. At high input current, this voltage will be lower than the 
battery voltage because of the voltage drop across the cable and connections. 
Ideally, the voltage should remain in the green area of the bar graph. If the 
voltage goes into the red area at the top and bottom of the graph, inverter may 
shut-down. The SW600 has a LED that changes colour from green to red as 
battery voltage 
decreases. 

 

5.3 Load watt indicator 

The AC load watt bar graph on the SW1500 indicates the power drawn from the 
power inverter. It will indicate watt by loads. For long-term operation, the watt 
should be in the green and orange area of the bar graph. The SW600 load level 
indicator should be green for long-term operation. Short-term operation is 
possible with the load indicator in the red area. If the load rises dangerous levels, 
the inverter will protect itself. The SW600 has a LED that goes from green to red 
at peak wattage.

 

Summary of Contents for GPSW-1500

Page 1: ...Pure Sine Wave Inverter GPSW 600 GPSW 1500 ________________________________________________ Owner s Manual...

Page 2: ...nd tools such as drills sanders grinders mixers and blenders The inverter must have a greater power rating then the load it provides power to To get the most out of the power inverter it must be insta...

Page 3: ...65 A 0 05 A Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Low Battery Alarm 2 10 5 V 21 V Low Battery Shut Down 2 10 0 V 20 0 V Operating Temperatur...

Page 4: ...Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Low Battery Alarm 2 10 7 V 21 4 V Low Battery Shut Down 2 10 3 V 20 6 V Operating Temperature Range 0...

Page 5: ...1500 a ON OFF switch Power ON OFF switch leave in the OFF position during installation b OVP over voltage protection c UVP under voltage protection d OTP over temperature protection e OLP over load p...

Page 6: ...result in an electrical safety hazard a Ventilation ports Do not obstruct allow at least 1 inch for air flow b Battery terminals Connect to 12V 24V battery or other 12V 24V power source is positive i...

Page 7: ...n during installation b Ventilation ports Do not obstruct allow at least 1 inch for air flow c Load Level Display AC load watts green indicates normal operation and red indicates high load levels d Fa...

Page 8: ...t Do not obstruct allow at least 1 inch for air flow b Battery terminals Connect to 12V battery or other 12V power source is positive is negative Reverse polarity connection will blow the internal fus...

Page 9: ...lines 1 Unpack and inspect your Go Power Inverter check to see that the power switch is in the OFF position Set up your power output according to Section 10 Configuring your Sine Wave 2 Insert DC inve...

Page 10: ...may permanently damage the inverter Damage caused by reverse polarity connection is not covered by our warranty Warning You may observe a spark when you make this connection since current may flow to...

Page 11: ...does not disconnect power from the power inverter When the switch is in the OFF position the power inverter draws no current from the battery When the switch is in the ON position but with no load th...

Page 12: ...as been operated at power levels above its rating or because it has been installed in a location which does not allow it to dissipate heat properly The power inverter will restart automatically once i...

Page 13: ...ections are good and the battery is charged but if the voltage still drops below 11 volts you may need to use a larger battery 6 2 Input voltage The power inverter will operate from input voltage rang...

Page 14: ...as possible Keep the cables between the battery and the power inverter as short as possible and twist them together with about 2 to 3 twists per foot This minimizes radiated interference from the cabl...

Page 15: ...to the return instructions detailed below and Go Power TM will repair or replace the Product and return it to the Purchaser free of charge or offer credit towards the purchase of new Product Go Power...

Page 16: ...e that is in any way attributable to the improper use storage maintenance installation or placement of the Go Power TM Product Failure caused by abuse misuse abnormal use or use in violation of any ap...

Page 17: ...concerning the Go Power TM Products other than the Warranty set out above The Buyer where permitted by applicable law hereby expressly waives any statutory or implied warranty that the Go Power TM Pr...

Page 18: ...product shipped collect to Go Power TM will be refused Test items or items that are not under warranty or units that are not defective will be charged a minimum bench charge of 50 00 US plus taxes and...

Page 19: ...GPSW 600 1500 ___________________________________________________________ 19 10 2 Configuring the GPSW 600 Switches are located on the front panel...

Page 20: ...GPSW 600 1500 ___________________________________________________________ 20 2011 GO POWER By Carmanah Technologies www gpelectric com MOBI_MAN_GPSW 600 1500_vE_Dec2011...

Reviews: