gpelectric.com | [page 33]
4.5.1 POWER SAVING MODE
Power Saving Mode is adjustable and set by the Dip Switches, S4, S5 and S6 on the front
panel. Example GP-SW1500TS: Saving set 2%, the load is below 30W 10 sec. will into saving
mode, more than 90W or more leave saving mode.
A.
Power device enter the saving mode
The rate power x setting % = the threshold enter the power saving model.
In case the load less than threshold value 5 seconds, the power device will enter the saving
mode.
B.
Power device leaving saving mode(re-start).
Restart threshold = rate power x setting % x 2~3
In case the power over the restart threshold, the power device will re-start and provide the
AC power.
S1
S2
S3
S4
S5
S6
S7
S8
Scenario
X
X
X
0
0
0
0
X
Power saving DISABLE
X
X
X
1
0
0
0
X
Go in power saving mode when output
load is under 2% of rating power
X
X
X
0
1
0
0
X
Go in power saving mode when output
load is under 3% of rating power
X
X
X
1
1
0
0
X
Go in power saving mode when output
load is under 4% of rating power
X
X
X
0
0
1
0
X
Go in power saving mode when output
load is under 5% of rating power
X
X
X
1
0
1
0
X
Go in power saving mode when output
load is under 6% of rating power
X
X
X
0
1
1
0
X
Go in power saving mode when output
load is under 7% of rating power
X
X
X
1
1
1
0
X
Go in power saving mode when output
load is under 8% of rating power
OPERATION