Page 3
After Each Use:
1. Set the pressure regulator switch to “Pressure Release”, and run the pump
with clean water to prolong the life of the pump.
2. Set the pressure regulating knob to “START” when the pump is not in use.
Maintenance:
1. Change the oil in the pump after the first 10-15 hours of use. After this,
change the oil in the pump after every 70 hours of use. NOTE: Always make
sure the oil is clean and visible thru the oil sight gauge Ref#11A before
operating.
2. Change or replace components, based on the symptoms as listed in the
trouble shooting section.
How to Change Oil:
1. Remove Ref # 12A Drain Plug. Allow the oil and any sludge to drain from
the crankcase into an EPA approved collection device.
2. Replace Ref # 12A Drain Plug once the crankcase has been drained.
3. Remove Ref # 7A Oil Fill Cap and fill crankcase with NON Detergent oil (see
chart) until the oil level reaches the center mark in Ref # 11A Oil Window.
4. Once filled, replaced Ref # 7A Oil Fill Cap.
Specifications
Maximum Flow…………………………………………………… 10 GPM
Maximum Pressure…………………………………………….. 600 PSI
Maximum RPM…………………………………………………. 800 RPM
Maximum Temperature…………………………………………. 140 F
Inlet Port…………………………………………………………………...1”
Outlet Port (Pressure)………………………………………………..3/8”
Outlet Port (Regulator Return Line)…………………….……...3/4”
Shaft Size……………………………………………….………………24mm
Dimensions:
Tall/Compact Mounted:………..…….19”H x 12”W x 15”L
Low Mounted…………………………... 14”H x 12”W x 15”L
Weight………………………………………….…………………….. 35 Lbs.
Engine Oil
Recommendations
Pump Oil
Non-Detergent
SAE30 Weight
NOTE: Not following proper procedures as listed in the detailed product manual may void
all warranties