IV. 

Maintenance

 

 

The computerized electronic meters can work at least 9,000 hours (one year) as the battery 
power. In most cases, the batteries are required to be replaced for one year. Prior to the 
demolition of the battery on sealed meter will extend batteries life. If the meter readings are 
dim or blanking, the battery should be replaced. PLS use batteries for Replacement from 
your distributor or factory. 

 

When the batteries are disconnected or damaged, circuits in batches and the total 
cumulative return to zero. Factory on-site check at the time still without power at the 
instrument computer. 

 

I strongly recommend checking the batteries and electrodes cleansing routine should be 
used as part of the process of maintenance. Battery electrode should be inspected once a 
year. No need to remove the instrument from the pipeline system, the batteries can be 
replaced . 

 

 

V. 

 

Batteries replacement

 

  Remove the four angle screws from the instrument’s control panel, take the 

computerized electronic instruments ( LCD screen ) from the turbine flow   

  Take out the batteries 

  Check battery electrode, if rust, and clear it. 

  Install new batteries, to ensure that the batteries are installed correctly, after the 

installation of the batteries, the the computer will be opened automatically, and display 
the reading information. 

  Install the electronic instrument ( LCD screen ) on the turbine flow meter, ensure that 

the O-ring is installed to right place. tighten the four screws   

  It is prohibited to use isopropyl alcohol to clean the external computer assembly. 

VI.

    

Assembly drawing

 

 

 

 

 

 

 

 

 

Tel:86-21-57632436                                                   Fax:86-21-57634942

Shanghai Cixi instrument Co., ltd

www. gnflowmeter.com

Summary of Contents for CX-WLTFM

Page 1: ...Usermanual CX WLTFM TURBINEFLOWMETER CX WLTFM TURBINEFLOWMETER Tel 86 21 57632436 Fax 86 21 57634942 Shanghai Cixi instrument Co ltd www gnflowmeter com ...

Page 2: ...flow coefficient k and user manual calibration of the flow coefficient k calibration 2 Functions as below Two cumulate which can be reset TTL1 cumulate Clear TTL2 the total accumulation can not clear zero it can be shifted by the buttons Unit selection The selection buttons to operate the flow units liters and gallons U S Sensor pulse frequency range 5Hz 5000Hz Low power consumption Two pieces of ...

Page 3: ...ss CALIBRATE can shift the unit LTR and GAL and the corresponding characters will be showed on the LCD display To press DISPLAY and CALIBRATE at the same time about 2 seconds will enter the user manual flow coefficient k calibration status B LCD Description TTL1 current flow can be cumulative in which can be cleared zero TTL2 current flow displayed is total cumulative in which can not be cleared z...

Page 4: ...ut about 30 seconds control panel will record the flow value calculate the flow coefficient k values and deposited CPU of the permanent preservation of non volatile memory even removed the battery discharge coefficient k will not lose value If the flow of calibration error over more than the limited 10 the panel will consider the current calibration value is invalid and will not record the current...

Page 5: ...0 L k l k Note l flow rate of flow meter k0 current flow not to amend before k value L0 user graduated cylinder measures the value Users to manually modify the k value for example Clear 0 TTL1 value or remove the batteries to clear TTL1 TTL2 0 fitted with batteries button is shifted to TTL1 status start the measurement of liquid flow the flowed liquid enters into the standard cylinder Record the d...

Page 6: ...tenance Battery electrode should be inspected once a year No need to remove the instrument from the pipeline system the batteries can be replaced V Batteries replacement Remove the four angle screws from the instrument s control panel take the computerized electronic instruments LCD screen from the turbine flow Take out the batteries Check battery electrode if rust and clear it Install new batteri...

Page 7: ...ilure 1 Removed the computer and if necessary check and reinstall or replace the batteries 2 Factory contact Normal flow rate but the instrument does not count when pressing the DISPLAY button the instrument boots 1 On site calibration method is not correct 2 Impeller jammed or damaged 3 Sealant material wrapped around the impeller 4 The computer failure Re check on site or check by Factory Remove...