background image

 

D5263 

- SIL 2 Load Cell/Strain Gauge Bridge Isolating Repeater 

G.M. International ISM0227-8 



Input from Zone 0 (Zone 20), installation in Zone 2. 



Strain Gauge Bridge Transparent Repeater. 



Up to four 350 

 load cells in parallel or up to five 450 

 load cells in parallel or up to ten 1000 

 load cells in parallel. 



High Accuracy. 



Three port isolation, Input/Output/Supply. 



EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system. 



ATEX, IECEx, EAC Ex, CCC, CML Certifications. 



Type Approval Certificate DNV and KR for maritime applications. 



High Reliability, SMD components. 



Simplified installation using standard DIN Rail and plug-in terminal blocks, with or without Power Bus. 



250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. 

20 

16 

15 
19 

18 

14 

17 

13 

1 2 3 4 

D5263 

5 6 7 8 

9 10 11 12 

PWR 

SIL 2 

13 14 15 16 

4 3 2 1 

8 7 6 5 

12 11 10  9 

17 18 19 20 

Front Panel and Features 

Terminal block connections 

Ordering Information 

 

Model:  

D5263S 

Power Bus and DIN-Rail accessories: 
Connector JDFT050 

 

 

Cover and fix MCHP196 
Terminal block male MOR017 

 

Terminal block female MOR022 

HAZARDOUS AREA 

SAFE AREA 

+ Output Ch 1 EXC (Weighting Indicator) 

1

 

+ Output Ch 1 Sense (Weighing Indicator) 

2

 

- Output Ch 1 Sense (Weighing Indicator) 

3

 

- Output Ch 1 EXC (Weighting Indicator) 

4

 

+ Output Ch 1 IN (Weighing Indicator)  

5

 

- Output Ch 1 IN (Weighing Indicator)  

6

 

+ Power Supply 24 Vdc 

9

 

- Power Supply 24 Vdc 

10

 

Not used 

11

 

Not used 

12

 

Not used 

7

 

Not used 

8

 

+ Input Ch 1 EXC (Load cell) 

13

 

+ Input Ch 1 Sense (Load cell) 

14

 

- Input Ch 1 Sense (Load cell)  

15

 

- Input Ch 1 EXC (Load cell) 

16

 

+ Input Ch 1 IN (Load cell) 

17

 

- Input Ch 1 IN (Load cell) 

18

 

Not used 

19

 

Not used 

20

 

Summary of Contents for D5263S

Page 1: ...263 SIL 2 Load Cell Strain Gauge Bridge Isolating Repeater G M International ISM0227 8 SIL 2 Load Cell Strain Gauge Bridge Isolating Repeater DIN Rail and Power Bus Model D5263S D5263S INSTRUCTION MANUAL ...

Page 2: ...esistance compensation 10 Ω Output Same as Input signal Output impedance 500 Ω typical Excitation voltage 4 0 V typical 15 V maximum Externally applied Transfer characteristic linear based on mV input Response time 100 ms 10 to 90 step change Performance Ref Conditions 24 V supply 23 1 C ambient temperature Calibration accuracy after system calibration 0 003 of full scale of input range Linearity ...

Page 3: ... to the instruments associated with the barrier 20 16 15 19 18 14 17 13 1 2 3 4 D5263 5 6 7 8 9 10 11 12 PWR SIL 2 13 14 15 16 4 3 2 1 8 7 6 5 12 11 10 9 17 18 19 20 Front Panel and Features Terminal block connections Ordering Information Model D5263S Power Bus and DIN Rail accessories Connector JDFT050 Cover and fix MCHP196 Terminal block male MOR017 Terminal block female MOR022 HAZARDOUS AREA SA...

Page 4: ...rs D5263 Associated Apparatus Parameters D5263 Terminals Function Diagram HAZARDOUS AREA ZONE 0 ZONE 20 GROUP IIC SAFE AREA ZONE 2 GROUP IIC T4 Uo Voc 7 2 V Ui Vmax 13 14 15 16 17 18 Io Isc 177 mA Ii Imax Po Po 471 mW Pi Pi Must be Hazardous Area Hazardous Locations Device Parameters D5263 Associated Apparatus Parameters Cenelec US D5263 Terminals IIC A B Co Ca 0 3 µF Ci Ci device C cable 13 14 15...

Page 5: ...t shall be installed in an enclosure that provides a minimum ingress protection of IP54 in accordance with IEC 60079 0 The enclosure must have a door or cover accessible only by the use of a tool The end user is responsible to ensure that the operating temperature of the module is not exceeded in the end use application Units must be protected against dirt dust extreme mechanical e g vibration imp...