- SIL3 24/220Vdc/Vac Transistor-Out Detector 

G.M. International ISM0541-2 

Ordering Information 

 

Front Panel and Features 

 



SIL 3 according to IEC 61508:2010 Ed.2 for Tproof = 6 / 20 years (

10% / >10 % of total SIF) 



PFDavg (1 year) 1.54 E-05, SFF 96.53 %. 



Systematic capability SIL 3. 



2 fully independent channels (only for D5093D-TB). 



Installation in Zone 2 / Safe Area. 



Input/Output and Channel/Channel isolation. 



EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system. 



ATEX, IECEx, UL & C-UL, EAC Ex, UKR TR n. 898, TÜV Certifications. 



TÜV Functional Safety Certification 



High Density, two channels per unit (D5093D-TB). 



Simplified installation on customized Termination Boards. 

24 to 220 Vac/Vdc Input Ch1 

Terminal block connections 

 

24 to 220 Vac/Vdc Input Ch2 (only for D5093D-TB) 

7

 

8

 

9

 

10

 

Model:   D5093 

1 channel 

2 channels 

-TB 

10 

SIL 3 

D5093

-TB 

STS 

STS 

7 8 

9 10 

Summary of Contents for D5093S-TB

Page 1: ...D5093 TB SIL3 24 220Vdc Vac Transistor Out Detector G M International ISM0541 2 SIL3 24 220Vdc Vac Transistor Out Detector Models D5093S TB D5093D TB D5093S TB D5093D TB INSTRUCTION SAFETY MANUAL...

Page 2: ...cal input ON 200 Vac Vdc OFF 160 Vac Vdc for 220 Vac Vdc typical input threshold level selection by means of internal dip switch Output voltage free SPST optocoupled open drain transistor solid state...

Page 3: ...one 2 Safe Area Input Output and Channel Channel isolation EMC Compatibility to EN61000 6 2 EN61000 6 4 EN61326 1 EN61326 3 1 for safety system ATEX IECEx UL C UL EAC Ex UKR TR n 898 T V Certification...

Page 4: ...A ZONE 2 GROUP IIC T4 NON HAZARDOUS LOCATIONS CLASS I DIVISION 2 GROUPS A B C D T Code T4 MODEL D5093D TB Out 1 SIL 3 10 7 8 Termination board connector Out 2 SIL 3 9 In 1 24 220 Vac In 2 24 220 Vdc 2...

Page 5: ...afety function but part of the circuit diagram and is listed for completeness When calculating the SFF this failure mode is not taken into account The 2 channels of D5093D TB module could be used to i...

Page 6: ...mplitude falls below the related lower threshold value the output transistor turns to the open state as detectable by the safety related PLC and the yellow status LED is turned off A dangerous failure...

Page 7: ...stened by a mixture of detergent in water Electrostatic Hazard to avoid electrostatic hazard the enclosure of D5093 TB series must be cleaned only with a damp or antistatic cloth Any penetration of cl...

Reviews: