Page 14
2669-RT / 3369-RT / 4069RT
Operating Instructions & Function Tests
Starting Engine from Upper Control Box
•
Lower Control Box:
Turn the Key Switch to PLATFORM.
•
Upper Control Box:
Turn the Engine Start Switch to START - release when the
engine starts.
•
Cold Start:
lift and hold the GLOW Switch as indicated in the Preheat table.
• With the GLOW Switch held, turn the START Switch until the engine starts.
• Release both switches once the engine starts.
• To protect the starter motor, power will cut off to the starter circuit when the starter
motor has run continuously for approximately 15 seconds without starting the
engine. The Starter Circuit Cutout indicator light will turn on and power to the starter
circuit will cut out for 30 seconds.
Preheat Table
Ambient Temperature
Preheat Time
Above 50°F (10°C)
5 Seconds
50°F to 23°F (10°C to –5°C)
10 Seconds
Below 50°F (–5°C)
20 Seconds
20 Seconds = Limit of Continuous Use
Be sure that the upper and lower EMERGENCY STOP Switches are reset.
1OP69