GB
19
Troubleshooting
Problem
Possible Cause
Suggested corrective action
No operation
Plug fuse
replace fuse
worn brushes
have brushes replaced by an authorised GMC service centre
power tool fault
contact an authorised GMC service centre
No sliding action
slide lock engaged
release slide lock
Stiff or rough sliding
action
build up of sawdust in mechanism
vacuum and lubricate mechanism
Cutting performance
poor
teeth worn or damaged
replace blade
Incorrect saw blade type
replace blade with correct type for material being sawed
Incorrect blade specification
Ensure blade meets the required blade specification for this mitre
saw
incorrectly fitted blade
remove blade and re-fit exactly as per the instructions in this manual
Power tool vibrating
excessively in use
saw blade distorted, bent or damaged
replace blade immediately
saw blade incorrectly mounted
re-fit blade exactly as per the instructions in this manual
machine fault
contact an authorised GMC service centre
Mitre position difficult to
adjust
build up of sawdust
vacuum up sawdust
PDF Compressor Pro