WATER SOFTENER INSTALLATION INSTRUCTIONS 

 
 
 

 

1)

 

Softeners should always be installed on firm level surface. 

 

2)

 

It is important that the water supply is within the pressure and temperature 
parameters. – 

Min- 1.7 Bar, Max 5.0 bar, Max Temp – 65 deg.C 

 

3)

 

The supplies to the softener should be capable of being isolated as close as possible 
to  the  softener  and  a  piped  by-pass  should  be  included  if  the  softener does  not 
already have one. 

 

4)

 

The  connections  should  be  made  with  flexible  hoses  with  regard  to  the  flow 
direction arrows on the connection manifold and the push fit hose connection for 
the  drain  should  be  run  to  an  open  faucet  to  prevent  syphonage.  If  the  unit  is 
supplied with a separate salt tank, you will need to connect the brine line from the 
push fit elbow to the brine tank, ensuring the brass inserts are fitted within the pipe. 

 

5)

 

The incoming supply to the softener should include a non-return valve. 

 

6)

 

The provision of an overflow in case of overfilling of the brine tank should also 
be provided to the “push fit” elbow on the side of the cabinet or brine tank. 

 

7)

 

Electrical connections should be made to a suitable socket outlet or D.P. isolation 
switch, fused at 3 amps. 

 

8)

 

Once installation is completed then please follow the below 
commissioning instructions. 

 

 

 
 
 