A note about spare drives

When 3 hard drives plus 1 spare drive are used, the total capacity will be only as large as two drives. When 

one drive fails, the data will be rebuilt immediately by using the spare drive, rather than waiting for the 

faulty drive to be replaced.

  

Using the ForteRAID with Pro Tools® Software

There is a current limitation with Pro Tools® and volume size. Pro Tools does not support record or playback 

on volumes 2TB or larger. This is currently an open issue that we expect will be resolved in future releases of 

Pro Tools. If using Pro Tools, choose a ForteRAID capacity and RAID mode that yields a volume 2TB or smaller. 

Using the ForteRAID with Windows 2000 / XP

Older versions of Windows, such as 2000 and XP 32-bit, use Master Boot Record which doesn’t support vol-

umes larger than 2TB. When the total capacity of the RAID is 2TB or higher, you must format the array using 

GPT in Windows. GPT format is only supported by Windows XP 64-bit Edition, Windows 2003 Server,  Win-

dows Vista, Windows 7, and Mac OS X. GPT format will not work with XP 32-bit or older Windows operating 

systems. If you want to use Windows 2000 and/or XP 32-bit, you’ll need to create a RAID that is less than 2TB. 

Front panel LEDs

The ForteRAID front panel has four LEDs. From left to right they are “Power”, “Check GM” (there are two of 

these which prompt you to open Glyph Manager software), and “Access”.  The Power LED will display solid 

blue when power is on.  The Access LED will flash green when there is disk activity.  The two Check GM LEDs 

will display a flashing or solid yellow when error conditions exits with the drives inside the array.  Those error 

conditions are discussed in greater detail below. If the Check GM LED is flashing or solid, connect via FireWire 

or USB, and open Glyph Manager software to diagnose the problem.

Summary of Contents for ForteRAID

Page 1: ...LYPH and if so such separate written agreement shall be controlling The information in this document is subject to change without notice and should not be construed as a commitment by GLYPH Although G...

Page 2: ...sturdy shipping container Please inspect the con tainer for evidence of shipping damage and mishandling If the container is damaged file a report with the carrier or dealer immediately Do not attempt...

Page 3: ...data mirroring each other If either of the drives should fail the other is there to seamlessly continue to provide operation RAID 3 striping with a dedicated parity drive offers speed and data redund...

Page 4: ...TB When the total capacity of the RAID is 2TB or higher you must format the array using GPT in Windows GPT format is only supported by Windows XP 64 bit Edition Windows 2003 Server Win dows Vista Wind...

Page 5: ...the ForteRAID It can be used for future functionality Setting up the ForteRAID NOTE It is advisable that the Glyph Manager software be installed prior to following the instructions below For informat...

Page 6: ...motherboards that include onboard eSATA The Glyph Manager screen display When installed in MAC OS X the left hand pane of the Glyph Manager screen displays general information regarding all Glyph enc...

Page 7: ...ating to excessive temperatures Temperature Individual drive temperatures are monitored as well as the temperature of the bridge the internal circuits Drive temperatures over 68 C is detrimental to co...

Page 8: ...in use in the array but that the data is being rebuilt Under normal operation this will not occur Occasionally after an improper shutdown for example if the unit was powered down while data was being...

Page 9: ...uire you to re format the ForteRAID and result in erasing all of the current data on the drive Make sure you backup all data before doing so To change the drive mode follow these steps 1 Install Glyph...

Page 10: ...ou to finalize the new configuration Click YES to accept the configuration change 3 Un mount the volume s associated with the unit you are configuring by dragging them to the trash in the Finder This...

Page 11: ...then selecting Show will invoke Glyph Manager to the screen NOTE With Vista Windows Defender will block the automatic launch of Glyph Manager Right click on the Windows Defender icon in the system tr...

Page 12: ...This setting only applies when us ing FireWire 800 The default Windows settings for FireWire connected drives can reduce your Glyph drive performance by as much as 90 This problem is easily corrected...

Page 13: ...d drive you must use a replacement drive with capacity equal to or higher than the existing drives in the array When building a new RAID array iden tical capacity drives are also recommended When usin...

Page 14: ...will be able to use the array during the rebuild process but performance will be degraded For RAID 0 and Spanning drive failure will result in the loss of the array You will need to create a new part...

Page 15: ...file called setup exe and then accept the End User Licensing Agreement Next accept or change the target install folder The installation will create a Start Menu folder by default Check the box marked...

Page 16: ...g Instructions 1 From your computer s task bar go to Start Programs MS DOS Prompt 2 At the prompt type fdisk and press Enter You ll see a long message about disk support 3 Enter Y type Y and press Ent...

Page 17: ...or the drive This name will identify the drive on the desktop 6 Click the Install Mac OS 9 Disk Driver button if you would like your drive to be compatible with OS 9 7 Click the Erase button to erase...

Page 18: ...0 Hi speed rear port Bridging Chip Oxford 936 Maximum Transfer Rate eSATA 300MB sec 3Gb sec Sustained Transfer Rate eSATA 230MB sec Dimensions H 7 x W 5 3 x D 9 6 Configuration Desktop enclosure Weigh...

Page 19: ...at 400 speed maximum FireWire is forward compatible and back compatible but the bus always runs at the speed of the slowest link Beta cables are used to connect 800 devices to 800 devices Bi Lingual...

Page 20: ...un in the last drive mode that it was set to Q What are the differences between FireWire 800 and FireWire 400 Speed and Protocol FireWire 800 has a max transfer rate of 800 Mb sec about 100 MB sec pea...

Reviews: