background image

26

METER MEMORY 

Reviewing Test Results

 

The meter stores the 1000 most recent blood glucose test results 

along with respective dates and times in its memory. To enter the 

meter memory, 

start with the meter off.

1. Press and release M button.

 will appear on the display. 

Press M button again, and the 

first  reading  you  see  is  the  last 

blood glucose result along with 

date, time and the measuring 

mode.

2. Press M button 

to recall the 

test results stored in the meter with 

each press.

3. Exit the meter memory 

After the last test result, press M 

button again and the meter will  

turn off.

Summary of Contents for TD-4277

Page 1: ...MANUAL OWNER S...

Page 2: ......

Page 3: ...Version 7 0 2014 9 311 4277100 035 MANUAL OWNER S...

Page 4: ...nts thoroughly and carefully Regular monitoring of your blood glucose levels can help you and your doctor gain better control of your diabetes Due to its compact size and easy operation you can use th...

Page 5: ...control checks as directed 7 Keep the device and testing supplies away from young children Small items such as the battery cover batteries test strips lancets and vial caps are choking hazards 8 Use...

Page 6: ...Test Strip 14 SETTING THE METER 15 THE FOUR MEASURING MODES 18 BEFORE TESTING 19 Control Solution Testing 19 Performing a Control Solution Test 19 TESTING WITH BLOOD SAMPLE 22 Preparing the Lancing De...

Page 7: ...29 Caring for Your Meter 30 Caring for Your Test Strips 32 Important Control Solution Information 33 SYSTEM TROUBLESHOOTING 33 Result Readings 33 Error Message 34 Troubleshooting 35 DETAILED INFORMAT...

Page 8: ...ing other substances will give incorrect results If you are experiencing symptoms that are inconsistent with your blood glucose test results and you have followed all instructions described in this ow...

Page 9: ...much pain as at the fingertip When to use AST Food medication illness stress and exercise can affect blood glucose levels Capillary blood at fingertip reflects these changes faster than capillary blo...

Page 10: ...not be used for the diagnosis of diabetes or testing on newborns Professionals may test with capillary and venous whole blood home use is limited to capillary whole blood testing Test Principle Your...

Page 11: ...product box They can be purchased separately Lancing Device with AST cap 2 x 1 5V AAA Alkaline Batteries Control Solution Test Strips Lancets Meter Owner s Manual Warranty Card Quick Start User Guide...

Page 12: ...the meter memory and silence a reminder alarm TEST STRIP SLOT WITH STRIP INDICATION LIGHT Insert test strip here to turn the meter on for testing DATA PORT Download test results with the cable connec...

Page 13: ...en Blood Drop Symbol Buzzer Test Result Ketone Warning Error Message Memory Mode Symbol Control Solution Mode Measuring Mode Test Strip Symbol Low Battery Symbol Measurement Unit Reminder Alarm Day Av...

Page 14: ...xus Test Strips Using other test strips with this meter can pro duce inaccurate results NOTE Contact Bars Insert this end of the test strip into the meter Push it in firmly until it will go no further...

Page 15: ...settings saved To Enter the Setting Mode Start with the meter off no test strip inserted Press SET to turn on the meter 1 Setting the date With the year flashing press and release M button to choose...

Page 16: ...SET 3 Setting the time With the hour flashing press and release M button to choose the correct hour Press SET With the minute flashing press and release M button to choose the correct minute Press SE...

Page 17: ...rip to begin testing If you do not press M button the meter will beep for 2 minutes then switch off If you do not want to test at this time press M button to switch off the meter Congratulations You h...

Page 18: ...C Modes Use when General displays as Gen any time of day regardless of time since last meal AC no food intake for at least 8 hours PC 2 hours after a meal QC testing with the control solution You can...

Page 19: ...strips you begin using a new vial of test strips you suspect the meter or test strips are not working properly your blood glucose test results are not consistent with how you feel or if you think the...

Page 20: ...ol solution do not directly apply control solution onto a strip 2 Press M button to mark this test as a control solution test With QC displayed the meter will store your test result in memory under QC...

Page 21: ...use only It is not a recommended range for your blood glucose level See the Maintenance section for important information about your control solutions Example only Please read exact range from your te...

Page 22: ...e blood extraction has a significant influence on the glucose value obtained Blood from a site that has not been rubbed exhibits a measurably different glucose concentration than blood from the finger...

Page 23: ...button to prick your finger then a click indicates that the puncture is complete Fingertip testing Choose a different spot each time you test Repeated punctures at the same spot may cause soreness and...

Page 24: ...ion discard the first drop of blood with a clean cotton swab Gently squeeze the punctured area to obtain another drop of blood Be careful NOT to smear the blood sample The volume of blood sample must...

Page 25: ...uble filling the confirmation window please contact your healthcare professional or the local customer service for as sistance NOTE 5 Read the Result The result of your blood glucose test will appear...

Page 26: ...rt with the meter off 1 Press and release M button will appear on the display Press M button again and the first reading you see is the last blood glucose result along with date time and the measuring...

Page 27: ...ch measuring mode in the order of Gen AC then PC 3 Exit the meter memory Keep pressing M button and the meter will turn off after displaying the last test result Any time you wish to exit the memory k...

Page 28: ...GlucoRx website http www glucorx co uk 2 Connecting to a personal computer 3 Data transmission Follow the instructions provided in the software to transmit data Results with date and time will be tra...

Page 29: ...nough to do a test Please change the batteries immediately Low Battery Signal The meter will display one of the below messages to alert you when the meter power is getting low Replacing the Battery To...

Page 30: ...dispose of the batteries according to your local environmental regulations NOTE Caring for Your Meter To avoid the meter and test strips attracting dirt dust or other contaminants please wash and dry...

Page 31: ...nlight and high humidity Meter Disposal The used meter should be treated as contaminated that may carry a risk of infection during measurement The batteries in this used meter should be removed and th...

Page 32: ...tightly Touch the test strip with clean and dry hands Use each test strip immediately after removing it from the vial Write the opening date on the vial label when you first open it Discard remaining...

Page 33: ...mperature range before testing Shake the vial before use discard the first drop of control solution and wipe off the dispenser tip to ensure a pure sample and an accurate result Store the control solu...

Page 34: ...t custom er services for assistance Appears when test strip is removed while counting down or insufficient blood volume Review the instructions and repeat test with a new test strip If the problem per...

Page 35: ...est with a new test strip Sample applied after automatic switch off 3 minutes after last user action Repeat the test with a new test strip Apply sample only when flashing appears on the display Defect...

Page 36: ...Fasting and before meal 4 to 7 mmol L 72 to 126 mg dL 2 hours after meals 9 mmol L 162 mg dL Source Diabetes UK Blood glucose target Balance No 234 2010 April P 69 Please work with your doctor to dete...

Page 37: ...37 SYMBOL INFORMATION...

Page 38: ...ter 3 minutes of idleness Temperature Warning Operating condition 10 C to 40 C 50 F to 104 F below 85 R H no condensing Meter Storage Transportation condition 20 C to 60 C 4 F to 140 F 95 R H Strip St...

Page 39: ...39...

Page 40: ...Wugong 2nd Rd Wugu Dist New Taipei City 248 Taiwan R O C www taidoc com MedNet GmbH Borkstra e 10 48163 M nster Germany Distributed by GlucoRx Ltd 4 Wintonlea Monument Way West Woking Surrey GU21 5EN...

Reviews: