12. Symbols and abbreviations

Consult instructions for use

Caution, consult instructions for use

Temperature limitation

Use by

Manufacturer

Batch code

In vitro diagnostic medical device

In vitro device for self-testing

Serial number

Recyclable package

CE marking

Contamination risk due to the use of blood samples

Blood glucose meter

Significant  additions  or  changes  from  previous  user 

manual revision

Direct current (voltage)

Catalogue number

The  meter  complies  with  the  requirements  of  directive  2011/65/EU  on 

the restriction of use of certain hazardous substances in electrical and 

electronic equipment and with the requirements of directive 98/79/EC on 

in vitro diagnostic medical devices.

11. Warranty

Your GlucoMen® areo 2K meter is guaranteed to be free of material and 

workmanship  defects  for  2  years  from  the  date  of  purchase  (except  as 

noted below). If at any time during the first 2 years after purchase, your 

GlucoMen® areo 2K meter does not work for any reason (other than as 

described below), it will be replaced with a new meter, or a substantial 

equivalent, free of charge. Should you wish to extend the warranty period 

for your meter, please refer to the warranty card.
This warranty is subject to the following exceptions and limitations:

 this warranty is only applicable to the original purchaser;

 this warranty does not apply to units which malfunction or are damaged 

due  to  obvious  tampering,  misuse,  alteration,  neglect,  unauthorized 

maintenance  or  failure  to  operate  meter  in  accordance  with  the 

Instructions;

 there  is  no  other  express  warranty  for  this  product.  The  option  of 

replacement, described above, is the warrantor’s only obligation under 

this warranty.

The original purchaser must contact A. Menarini Diagnostics: Telephone 

Number XXXXXXXX.

A. Menarini Diagnostics is committed to using your personal information 

responsibly and in compliance with the law. You have our pledge that we 

will not disclose or sell your personal information with third-parties.

The information you voluntarily provide will be used to help us serve you 

better in the future.

Summary of Contents for Areo 2k

Page 1: ... Ketone Self Monitoring System 2 System overview 2 1 Meter FRONT TEST STRIP PORT UP DOWN BUTTONS ENTER BUTTON TEST STRIP PORT Test strip should be inserted here ENTER BUTTON Press and hold for 2 seconds to access meter memory 6 1 or longer 4 seconds to enter setup mode while not testing 7 UP DOWN BUTTONS Press or to scroll through different options and or values BACK BATTERY HOLDER NFC ANTENNA DAT...

Page 2: ...Sensor or GlucoMen areo β Ketone Sensor only Do not use other test strips it causes inaccurate test results Do not use test strips after their expiry date The expiry date is either written on the test strip vial next to the symbol glucose sensor or on the foil pouch β ketone sensor For accurate test results allow the meter and test strips to adjust to the surroundings for at least 30 minutes befor...

Page 3: ...culating averages Always select the ctl icon before conducting a control solution test or the results may fall outside the acceptable range To enable the ctl icon just press one of the UP DOWN buttons once while the drop icon is blinking on the screen 3 Gently shake the control solution vial before testing Discard a drop before use Squeeze a drop of control solution onto a clean hard dry surface 4...

Page 4: ... Gently shake the control solution vial before testing Discard a drop before use Squeeze a drop of control solution onto a clean hard dry surface 4 Touch the control solution drop with the tip of the test strip until the check window is full A beeper will sound if enabled as the countdown timer starts on the screen NOTE The test will not start if you apply your control solution directly to the che...

Page 5: ...y set 1 The display will show the alarm clock and the Glu icons both blinking Press or to scroll between glucose Glu icon blinking and β Ketone Ket icon blinking alarm section Press to confirm the selection and move on to the next step In the following steps either Glu or Ket icon will be shown indicating the selected alarm section 2 The display will show alarm 1 status the default setting is OFF ...

Page 6: ...eries as follows 1 Make sure the meter is switched off 2 Remove the battery cover at the rear of the meter 3 Remove the batteries 4 Fit the new batteries into the battery holder with the pole facing upwards 5 Close the battery holder WARNING If the batteries are inserted upside down the meter will not operate The meter clock may stop if you touch the metal parts inside the meter with your hands or...

Page 7: ... icon flashing After 45 seconds of inactivity after the test and Error messages Err2 Err3 Err4 HI and LO After 5 seconds for Error messages Err1 Err5 Temperature icon and Battery icon Dimensions 85 5 mm L x 56 mm W x 18 2 mm H Weight 46 g without batteries Meter Operating Conditions Temperature 5 to 45 C 41 to 113 F for glucose testing 10 to 40 C 50 to 104 F for β ketone testing Relative Humidity ...

Page 8: ...areo 2K meter is guaranteed to be free of material and workmanship defects for 2 years from the date of purchase except as noted below If at any time during the first 2 years after purchase your GlucoMen areo 2K meter does not work for any reason other than as described below it will be replaced with a new meter or a substantial equivalent free of charge Should you wish to extend the warranty peri...