GLP
German Light Production
(V1.05)
17
3.9.11 Correction of faults
(EFLG)
EFLG
(Function available for authorized persons only)
3.10 Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes
after having switched off (lamp too hot). The message will appear on
the display if the lamp doesn’t ignite within 20 seconds. The fixture will
store this command and automatically ignite the lamp after 5 minutes.
LaeR
After the ignition of the lamp was two times not successful the display
will show
LAER
. That means the lamp could be damaged or even
missed, the fixture is overheating or there could be a failure on the
igniter or ballast. Switch off the power supply and solve the possible
problem.
OTMP
This error message informs you that the fixture was overheating and
that the relay switches off the lamp. Pleas look for possible reasons (fan
faulty, air in/outlets blocked or very dirty, lamp broken or very old, too
high ambient temperature. Switch off the power supply and solve the
possible problem.
RsER
This message informs you that one of the fixture function wasn’t able to
do its reset correct (magnetic sensor, stepping motor, driver on the
PCB, cables, etc.). Repair the defect and start the fixture again.
4
DMX Channel Selection (DMX Protocol)
Channel
Function
Time and Value
DMX
HEX
%
1) PAN-
coarse
0 .. 530°
min. 2,65 s
0..255
00..FF 0..100
2) PAN-fine
High- Pos ... High- Pos + 2,1° (16 Bit)
0..255
00..FF 0..100
3) Tilt-
coarse
0 .. 285°
min. 1,8 s
0..255
00..FF 0..100
4) Tilt-fine
High- Pos … High- Pos + 1,1° (16 Bit)
0..255
00..FF 0..100
5) Color
open (fast)
0..1
00..01
0,2
open / color 1 (fast)
2..3
02..03
1,0
color 1, Brilliant Blue (fast)
Chaser from color to
color max. 140 BPM
=> 0,43 s
4..5 04..05
1,8
color 1 / color 2 (fast)
6..7
06..07
2,5
color 2, Blue (fast)
8..9
08..09
3,3
color 2 / color 3 (fast)
10..11
0A..0B 4,1
color 3, Blue Purple (fast)
12..13
0C..0D 4,9