3.9.8 Adjustments and Calibrations
(ADJU)
ADJU
By this function you can adjust and calibrate the positions of the different
wheels and other motors. This can be necessary after a service or repair
work.
For this function you have to entry the fixture code. This work should be
done only by authorized persons.
Use the
Up/Down-
keys to select desired function and press
Enter
to
confirm or
Mode
to cancel and return to the menu. Use now the
Up/Down-
keys to set the adjustment values and confirm once more with the
Enter-
key or cancel with the
Mode-
key.
Function
Value
Remark
ADJU CODE
xxxx
Adjustments in the internal setup are code protec-
ted (for authorized persons only).
COLO - 99 - + 99
Adjustment of the Color wheel
GOB1 - 99 - + 99
Adjustment of the Gobo wheel 1
GOB2 - 99 - + 99
Adjustment of the Gobo wheel 2
PRIS - 99 - + 99
Adjustment of the Prism wheel
SHTR - 99 - + 99
Adjustment of the Shutter
POFS - 99 - + 99
Adjustment of the Pan-Offsets
TOFS - 99 - + 99
Adjustment of the Tilt-Offsets
ARES - 99 - + 99
Adjust Reset (wheels stand still after the reset)
CLRE
Adjustments in the internal circuit.
FACC - 99 - + 99
Must switched to
ON
(code protected)
VTIL - 99 - + 99
Software version of Tilt-board
VTOP - 99 - + 99
Software version of Head- board
VBOT - 99 - + 99
Software version of Base- board
FASP - 99 - + 99
Indication of the Fan-Speed
3.9.9 Default Settings
(DFSE)
DFSE
Press
Enter
to reset all fixture personalities (not the adjusted functions) to
the default values. On the display will appear
ok
to indicate that the de-
faults are set.
Function
Display
Default Settings
DMX Address
D001
D001
Pan reverse
RPAN
ON
OFF
9
Tilt reverse
RTLT
ON
OFF
9