GLP X4 atom PSU 12 Instruction Manual Download Page 19

                                                                                      

GLP German Light Products 

 

X4 Atom PSU12 manual (v1.0)  

from software version: v1.21

 

19 

     

Shutter Open 

  

95..100 

239..255 

104  Color (fixed) 

Colors adjustable via RGB 

  

0..2 

0..7 

     

Color 01 - Red 

1)

 

  

3..5 

8..15 

     

Color 02 - Amber 

1)

 

  

6..8 

16..23 

     

Color 03 - Warm Yellow

 1)

 

  

9..12 

24..31 

     

Color 04 - Yellow 

1)

 

  

13..15 

32..39 

     

Color 05 - Green 

1)

 

  

16..18 

40..47 

     

Color 06 - Turquoise 

1) 

 

  

19..21 

48..55 

     

Color 07 - Cyan 

1)

 

  

22..24 

56..63 

     

Color 08 - Blue 

1)

 

  

25..27 

64..71 

     

Color 09 - Lavender 

1)

 

  

28..30 

72..79 

     

Color 10 - Malve 

1)

 

  

31..34 

80..87 

     

Color 11 - Magenta 

1)

 

  

35..37 

88..95 

     

Color 12 - Pink 

1)

 

  

38..40 

96..103 

     

White - CTO 

3200K 

41..43 

104..111 

     

White 

5600K 

44..46 

112..119 

     

White - CTB 

7200K 

47..49 

120..127 

     

Rainbow Effect Stop 

2)

 

  

50 

128 

     

Rainbow Effect

 3)

 

slow - fast 

51..88 

129..223 

     

Random colors 

slow - fast 

89..100 

224..255 

105  Red 

Color mixing system - Red 

0 - 100% 

0..100 

0..255 

106  Green 

Color mixing system - Green 

0 - 100% 

0..100 

0..255 

107  Blue 

Color mixing system - Blue 

0 - 100% 

0..100 

0..255 

108  White 

Color mixing system - White 

0 - 100% 

0..100 

0..255 

109  Zoom 

Wide (flood) - narrow (spot)  

34° - 3.5° 

0..100 

0..255 

110  CTO 

No function 

Applicable for 

0..3 

0..7 

     

Variable CTO (10,000K - 2,700K) 

all colors 

4..100 

8..255 

 

1)

 The predefined colors can be used as start-colors for the Rainbow effect. Please select 

first a desired start-color before you activate the rainbow effect. All X4 Atom will then start 
from that color and will execute the rainbow effect synchronously. Different X4 Atom can 
have  different  start-colors  but  will  still  execute  the  rainbow  effect  synchronously.  If  you 
choose a color different from the ones marked with 

1)

 in the tables above the rainbow 

start-color will be red.  
 

2)

 Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be 

continued from the current color.  
 

3)

  The  Rainbow-effect  will  run  synchronously  only  if  started  from  one  of  the  predefined 

colors (see also 

1)

 before).   

 
 
 
 
 
 

 
 
 

Summary of Contents for X4 atom PSU 12

Page 1: ...from software version v1 21 support glp de www glp de Instruction Manual PSU12...

Page 2: ...ck 5 3 2 Mounting in a hanging or sideways position 5 3 3 Securing the Fixture 6 4 Connections 7 4 1 Power Supply 7 4 2 DMX 8 4 3 Output to X4 ATOM Head 8 5 The Menu Field 8 6 DMX Channel Selection DM...

Page 3: ...LCD Display Menu data entry 2 Safety wire attachment point 2x 3 Fan in outlet 2x 4 Connector panel see below 1 2 3 4 5 6 7 8 9 10 11 5 Mains switch on off 6 Micro fuse 5 x 20mm T5A 250V 7 12 x Output...

Page 4: ...common rules of technology that are not explicitly mentioned in this manual 6 Use only original GLP spare parts Any structural modification of the system will terminate all warranty claims 7 Please k...

Page 5: ...r on a table or in a Rack The X4 ATOM PSU 12 can directly placed on the floor a table or inside a rack An additional securing is usually not required Please pay attention to an even and gripping surfa...

Page 6: ...ty wire Attach the safety wire through the attachment point shown below and connect it to the primary support structure Pay attention to a safe and proper fastening The safety cable must comply with B...

Page 7: ...PSU 12 is fitted with NEUTRIK powerCON locking 3 conductor AC connectors The grey connector must be used to draw AC mains power from the fixtures throughput sockets and the blue connectors must be us...

Page 8: ...e PSU and or the connected fixture s 5 The Menu Field DOWN UP MODE ENTER Level1 Level 2 Level 3 Level 4 Remark DMX Start Address 001 Set the DMX start address Special Manual DMX Manual control of all...

Page 9: ...y contrast PWM Frequ Adj Changes PMW frequency Max Zoom adjust Calibration of Zoom offset LED adjust White adjust red Adjust intensity for red channel White adjust blue Adjust intensity for blue chann...

Page 10: ...taneous value for Shutter White Instantaneous value for White Blue Instantaneous value for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wheel Instantaneous value for...

Page 11: ...0 5 sec 98 100 248 254 Output 1 3 Intensity Intensity 0 100 0 100 0 255 4 Shutter Shutter closed 0 5 0 15 Random strobe random slow fast 6 18 16 47 Ramp up random slow fast 19 31 48 79 Ramp down rando...

Page 12: ...ast 63 77 144 199 Strobe Slow to Fast random slow fast 78 98 200 239 Shutter Open 95 100 239 255 14 Color fixed Colors adjustable via RGB 0 2 0 7 Color 01 Red 1 3 5 8 15 Color 02 Amber 1 6 8 16 23 Col...

Page 13: ...Rainbow Effect Stop 2 50 128 Rainbow Effect 3 slow fast 51 88 129 223 Random colors slow fast 89 100 224 255 24 Red Color mixing system Red 0 100 0 100 0 255 25 Green Color mixing system Green 0 100 0...

Page 14: ...obe with b o pause random slow fast 63 77 144 199 Strobe Slow to Fast random slow fast 78 98 200 239 Shutter Open 95 100 239 255 41 Color fixed Colors adjustable via RGB 0 2 0 7 Color 01 Red 1 3 5 8 1...

Page 15: ...w fast 89 100 224 255 51 Red Color mixing system Red 0 100 0 100 0 255 52 Green Color mixing system Green 0 100 0 100 0 255 53 Blue Color mixing system Blue 0 100 0 100 0 255 54 White Color mixing sys...

Page 16: ...tter Open 95 100 239 255 68 Color fixed Colors adjustable via RGB 0 2 0 7 Color 01 Red 1 3 5 8 15 Color 02 Amber 1 6 8 16 23 Color 03 Warm Yellow 1 9 12 24 31 Color 04 Yellow 1 13 15 32 39 Color 05 Gr...

Page 17: ...en 0 100 0 100 0 255 80 Blue Color mixing system Blue 0 100 0 100 0 255 81 White Color mixing system White 0 100 0 100 0 255 82 Zoom Wide flood narrow spot 34 3 5 0 100 0 255 83 CTO No function Applic...

Page 18: ...1 6 8 16 23 Color 03 Warm Yellow 1 9 12 24 31 Color 04 Yellow 1 13 15 32 39 Color 05 Green 1 16 18 40 47 Color 06 Turquoise 1 19 21 48 55 Color 07 Cyan 1 22 24 56 63 Color 08 Blue 1 25 27 64 71 Color...

Page 19: ...stem Green 0 100 0 100 0 255 107 Blue Color mixing system Blue 0 100 0 100 0 255 108 White Color mixing system White 0 100 0 100 0 255 109 Zoom Wide flood narrow spot 34 3 5 0 100 0 255 110 CTO No fun...

Page 20: ...ooling will be significantly reduced or damages can occur Regular cleaning will not only ensure the maximum performance but will also allow the fixture to operate reliably throughout its life 7 1 Safe...

Page 21: ...00ft per output Fuse protection Micro fuse 5x20 mm T10A Operational Parameters Max Ambient Temperature 5 45 C integrated overheating switch 40 113 F Protection IP20 rated Mounting Position Any see rel...

Page 22: ...GLP German Light Products X4 Atom PSU12 manual v1 0 from software version v1 21 22 9 Dimensions...

Page 23: ...GLP German Light Products X4 Atom PSU12 manual v1 0 from software version v1 21 23...

Reviews: