![Glow-worm Ultimate 3 Installation And Maintenance Instructions Manual Download Page 8](http://html1.mh-extra.com/html/glow-worm/ultimate-3/ultimate-3_installation-and-maintenance-instructions-manual_2234605008.webp)
8
Installation and maintenance instructions Ultimate 3 0020239568_03
4
Notes on the documentation
▶
Always observe all operating instructions enclosed with
the installation components.
▶
Store these instructions and all other applicable docu-
ments for further use.
These instructions apply only to:
Product article number
Article number
Gas Council
Number
ULTIMATE 3 25r -A (H-
GB)
0010021408
41-019-52
5
Product description
5.1
CE marking
The CE marking shows that the products comply with the
basic requirements of the applicable directives as stated on
the declaration of conformity.
The declaration of conformity can be viewed at the manufac-
turer's site.
5.2
Hot Water Association
Vaillant is a full member of the Hot Water Association and
promotes the scheme in association with its cylinder range.
Details are available on the web site www.vaillant.co.uk
5.3
Serial number
1
2
The serial number is located on the data plate
(1)
.
Stickers showing the serial number are on the rear of the
electronics box
(2)
.
5.4
Information on the data plate
The data plate is mounted on the underside of the product at
the factory.
Information on the
data plate
Meaning
Barcode with serial number
Serial number
For quality control purposes; 3rd and 4th
digits = year of production
For quality control purposes; 5th and 6th
digits = week of production
For identification purposes; 7th to 16th
digits = product article number
For quality control purposes; 17th to 20th
digits = place of manufacture
ULTIMATE 3 25r -A
(H-GB)
Product designation
2H, G20
–
20 mbar
(2 kPa)
Factory setting for gas type and gas
connection pressure
Cat.
Approved gas category
Condensing techno-
logy
Efficiency class of the boiler in accord-
ance with EC Directive 92/42/EEC
Type: Xx3(x)
Permissible flue gas connections
PMS
Maximum water pressure in heating
mode
PMW
Maximum water pressure in domestic hot
water mode
V / Hz
Electrical connection
W
Max. electrical power consumption
IP
IP rating
Heating mode
P
n
Nominal heat output range in heating
mode
P
nc
Nominal heat output range in heating
mode (condensing technology)
P
Nominal heat output range in domestic
hot water mode
Q
n
Nominal heat input range in heating
mode
Q
nw
Nominal heat input range in domestic hot
water mode
T
max.
Max. flow temperature
NOx
NOx class for the product
Code (DSN)
Specific product code
Read the instructions.
GC no.
Gas council number