Supplied By www.heating spares.co Tel. 0161 620 6677
6
221474C
Diagram 4
WATER VALVES
SLOT(OPEN)
DRAIN
POINT
COLD WATER
SUPPLY IN
HEATING
FLOW
GAS
SERVICE
COCK
HEATING
RETURN
2793
HOT
WATER
OUT
SAFETY
VALVE
DISCHARGE
SLOT(OPEN)
Pressure Relief Safety Valve
CAUTION. A pressure relief safety valve and discharge pipe is
fitted to the boiler. This valve must not be touched. Should there
be any discharge from the pipe, turn the boiler off, isolate from the
electrical supply and contact your installation/servicing company.
Cleaning
WARNING. This appliance contains metal parts (components) and
care should be taken when handling and cleaning with particular
regard to edges.
The boiler casing can be cleaned using a mild liquid detergent with
a damp cloth, then a dry cloth to polish.
Do not use any form of abrasive or solvent cleaner as you may
damage the paint work
Boiler Casing
CAUTION. Do not remove or adjust the casing in any way, as
incorrect fitting may result in incorrect operation or failure to operate
at all. If in doubt seek advice from the local gas company or your
installation/ servicing company.
Replacement Parts
If replacement parts are required apply to your local supplier or
British Gas.
Please quote the name of the appliance.
Instructions for Use
✽
Increase to 25mm clearance from
combustible material
0183M
✽
5
800
✽
5
5
5
140
150
✽
5
Diagram 5
125
ele
Diagram 3
6504
Orange Light 'MAINS'
Green Light 'RUNNING'
Red Light 'LOW C.H. WATER
PRESSURE'
5044
SWITCH
'ON'
CONTROL
RESET
BUTTON
SWITCH
'OFF'
PRESSURE GAUGE
‘A’
CENTRAL HEATING
SELECTOR SWITCH
'C'