7 F l u e P r e p a r a t i o n
2334
2302
Diagram 7.5
INTERNAL ACCESS
FLUE
TERMINAL
AIR
DUCT
SEAL
OUTSIDE
WALL FACE
WALL
SLEEVE
Diagram 7.4
FLUE AIR DUCT
FLUE
ELBOW
SCREW (2)
AIR DUCT
FLUE DUCT
FLUE
TERMINAL
TAPE
3.3 DIA
HOLE IN EACH SIDE
OF THE AIR DUCT
7.4 Air Duct
Locate the flue duct and air duct in the flue elbow,
making sure that the flue duct is located in the flue
terminal and the flue elbow but is free to move to allow
for expansion.
Check that the flue terminal is in the correct position and
sticking out the correct distance from the outside wall
face, see diagram 7.1 and appropriate diagram 7.2 or 7.3.
Drill a hole, diameter as shown in diagram 7.4, in each
side of the air duct, through the holes in the flue elbow.
Secure the air duct to the flue elbow using the two
screws supplied in the loose items pack.
Seal around the joint between the air duct and the flue
elbow using the tape provided in the loose items pack.
Stick the self-adhesive seal, supplied in the loose items
pack, around the air duct, in a position so that it will be
flush with the outside wall when installed, see
diagram 7.5.
If the boiler is not to be fitted for some time, cover the
hole in the wall.