Supplied By www.heating spares.co Tel. 0161 620 6677
3
220692C
3
SECTION
General
1
3060
The instructions consist of two parts,
Installation and Servicing Instructions
and Instructions for Use, which includes
the Guarantee Registration Card. The
instructions are an integral part of the
appliance and must, to comply with the
current issue of the Gas Safety
(Installations and Use) Regulations,be
handed to the user on completion of
the installation.
Important Notices
This boiler is for use on natural gas
(G20) as distributed in the United
Kingdom and cannot be used on any
other gas.
Wherever possible, all materials,
appliances and components to be used
shall comply with the requirements of
applicable British Standards.
Where no British Standard exists,
materials and equipment should be fit for
their purpose and of suitable quality and
workmanship.
This boiler must have fully pumped
circuits, but is suitable for use with open
vented or sealed water systems.
This boiler is not suitable for outdoor
locations.
Sheet Metal Parts
WARNING. When installing or
servicing the boiler care should be taken
when handling sheet metal parts to avoid
any possibility of personal injury.
Statutory
Requirements
The installation of the boiler MUST be
carried out by a competent person in
accordance with the relevant
requirements of the current issue of:
Manufacturer’s instructions supplied.
55
70
35
R F
WATER CONNECTIONS
28mm COMPRESSIONS
GAS CONNECTION
Rc
1
/
2
(
1
/
2
"B.S.P.T.)
TOP VIEW
450
40
285-
315
SIDE
FLUE
OUTLET
130
700-
728
125
458
FRONT VIEW
445
155
125
SIDE VIEW
REAR
FLUE
OUTLET
687
50
15
FRONT VIEW
BOILER OUTLINE
102
63
FLUE
TERMINAL
DETAIL
ALL DIMENSIONS ARE IN MILLIMETRES