5 I n s t a l l a t i o n
2480
Diagram 5.4
2465
UNION
NUT
GAS
SUPPLY
TUBE
NUT (A)
NUT (B)
UNION NUT
OLIVE
GAS
SERVICE
COCK
JOINT (C)
5.2 Gas and Electrical Connection
Place the tubing nut and olive, from the loose items
pack, onto the prepared end of the gas supply tube, see
diagram 5.4.
Connect the gas supply, as diagram 5.4, tighten the nut
and olive at the gas service cock.
To tighten the other end use a spanner to lock the
hexagon nut (A) at the bulkhead fitting and make sure
that it does not turn, tighten the nut (B) on the supply
tube in the usual manner, see diagram 5.4.
Make sure that joint (C) is checked for gas soundness,
as Section 6.1.
Connect the plug and socket as shown in diagram 5.5.
Make sure that the socket is fully engaged into the plug
on the fire front.
Note, when removing fire front do not break the union
nut connection at gas service cock, see diagram 5.4.
SOCKET
PLUG
SWITCH
Diagram 5.5
6 L i g h t i n g a n d T e s t i n g a n d F i t t i n g I n t e r n a l P a r t s
2465
Diagram 6.1
KNOB IN 'OFF'
POSITION
Push in and turn
anti-clockwise
GAS
RATE
IGNITION
6.1 Lighting and Testing
Make sure that the electrical supply to the back boiler is
isolated.
The fire front is fitted with a Combustion Products
Discharge Safety Device which will shut it down if there
is a lack of oxygen. If the fire shuts down frequently for
no apparent reason the first things to be checked are the
chimney and air inlets into the room. An additional
cause could be that the filter, in the gas tap has become
blocked. Any problems found must be put right, by a
competent person before the fire is used again.
The combustion products discharge safety device
MUST NOT be adjusted or disconnected.
If replacing use only the correct and approved parts.
Make sure that the flat on the drive rod faces the wall
before fitting the control knob, see diagram 6.1.