Glow-worm Climapro 2 RF Installation Instruction Download Page 4

0020094581_01 - 08/10 - Glow-worm

- 2 -

INTRODUCTION

INTRODUCTION

1  Instructions guidance

1.1 

Product documentation

The instructions are an integral part of the Climapro

2

 RF and 

must be handed to the user on completion of the installation in 

order to comply with the current regulation.

•  Carefully read the manual, to enable safe installation, use 

and servicing. No liability can be accepted in the event 

of damage for not complying with the guidance in this 

instruction manual. 

• 

Associated documents 

 - User instructions

1.2 

Explanation of symbols

e

DANGER: Risk of electric shock.

ATTENTION: Risk of damage to the Climapro

2

 RF 

or to its vicinity.

IMPORTANT: Useful information.

2  Climapro

2

 Rf description

2.1 

Regulation and statutory requirements

CE Mark 

he CE mark indicates that the appliances described in this 

manual are in compliance with the following directives:

 - European Directive Num. 2004-108 of the European 

Parliament and the Council regarding electromagnetic 

compatibility

 - European Directive Num. 2006-95 of the European 

Parliament and the Council regarding low voltage

 - Directive relating to telecommunications equipment (Council 

of the European Community directive R&TTE 99/5/CEE).

2.2 

Operational Diagram

The room thermostat communicates with a control unit via a 

wireless connection.

1

2

3

4

Legend

1  Wall support for Climapro

2

 Rf

2  Control unit

3  Room thermostat 

4  batteries

3  Safety instructions and regulations

3.1 

Safety instructions

All work inside Climapro

2

 RF must be carried out by a qualified 

professional or Glow-worm’s After-Sales Service.

Climapro

2

 RF must only be installed by a qualified and 

responsible professional.

Respect the basic safety instructions:

•  Turn off the control unit’s power supply.

•  When work on the appliance is completed, perform an 

operational test and check for safety.

3.2 

Regulations

During the installation and activation of the appliance, the 

decrees, directives, technical regulations, standards and 

clauses hereafter must be complied with in the versions that are 

currently in force.

Summary of Contents for Climapro 2 RF

Page 1: ...Climapro2 RF www glow worm co uk Installation wireless room thermostat without receiver ...

Page 2: ......

Page 3: ...on 4 6 1 Dimensions 4 6 2 List of contents 4 7 Fixing 5 7 1 Fixing the room thermostat 5 8 Electrical connections 5 8 1 Pairing recognition 5 9 Commissioning 5 9 1 Appliances included in the installation 5 9 2 Room thermostat 5 10 Specific settings 6 10 1 Main settings 6 10 2 Access to the installer menu 6 10 3 Description of the installer menu 6 10 4 Heating function 6 10 5 Domestic hot water fun...

Page 4: ...iament and the Council regarding electromagnetic compatibility European Directive Num 2006 95 of the European Parliament and the Council regarding low voltage Directive relating to telecommunications equipment Council of the European Community directive R TTE 99 5 CEE 2 2 Operational Diagram The room thermostat communicates with a control unit via a wireless connection 1 2 3 4 Legend 1 Wall suppor...

Page 5: ...d for energy recovery reuse or recycling Take the unit to an appropriate collection point for processing energy recovery and recycling of waste By complying with this directive you will contribute to the preservation of natural resources and the protection of human health 4 2 Packaging We recommend that you recycle the packaging of Climapro2 RF in a responsible fashion Sort the waste in order to s...

Page 6: ...nd grease on cold walls between units or behind curtains or other objects that might disturb temperature recording for the ambient air in the room in a room that is heavily loaded with dust or where the atmosphere is corrosive near air currents that may come from doors or windows 1500 6 Climapro2 RF Installation All of the measurements in this chapter are expressed in mm 6 1 Dimensions 6 1 1 Room ...

Page 7: ...oom thermostat support 4 with screws 2 Slide the room thermostat 6 into its support 4 8 Electrical connections 8 1 Pairing recognition See the installation manual control unit The Climapro2 RF and the Systempro control unit must be paired 9 Commissioning 9 1 Appliances included in the installation Turn on the appliances that make up the installation see the installation manuals 9 2 Room thermostat...

Page 8: ...F Efficient energy use Energy efficiency index Enable YES or disable NO default setting OFF 10 2 Access to the installer menu Press button for 7 seconds Enter the installer access code 96 10 3 Description of the installer menu Menu Browsing Use the buttons Select with the button Press the button to return to the installer menu screen for 3 seconds to return to the user s main screen Showing enabli...

Page 9: ... access to the installer menu select on the screen hot water on off Press to highlight your choice activate or deactivate and press the button to confirm 10 5 2 To activate or deactivate the domestic hot water heating program The hot water function must be activated before the program can be set up Depending on the appliance deactivation cuts off the hot water heating as well as the production of ...

Page 10: ... software version for the room thermostat 10 7 1 System efficiency information This function allows the user to activate or deactivate the system efficiency information Via the installer menu see installer menu select settings effic info on the screen Press to highlight your choice activate or deactivate and press the button to confirm 10 7 2 Setting the current date From the installer menu see ac...

Page 11: ...ensor 10 8 1 Recognition This function lets you perform the pairing between the Climapro2 RF and the radio receiver From the installer menu see access to the installer menu select on the screen RF pairing Consult the control unit installation manual 10 8 2 Test This function allows you to test the signal quality between the Climapro2 RF and the control unit If the heating system includes a wireles...

Page 12: ...ation At the end of the installation explain the operation of the appliance and its safety devices to the user if necessary provide a demonstration and answer any questions give the user all the required documentation fill in the documents where necessary advise the user of the precautions necessary to prevent damage to the system appliance and the building remind the user to service the appliance...

Page 13: ...nosis Faults described in this chapter should be carried out by a qualified engineer and if needed by the After Sales Service You will find a list of certain error codes in the user manual In the event of a problem Check the error messages in the thermostat s display zone ...

Page 14: ...at min 10 Average unobstructed working range m 100 Average range within the home m 25 Can vary according to installation conditions and electromagnetic environment Room thermostat Room temperature authorized in the room where the appliance is installed C 50 Dimensions Height mm 173 Width mm 62 5 Depth mm 34 Supply 4 AA LR6 alkaline batteries V 4 x 1 5 Battery life month 18 Under normal conditions ...

Page 15: ......

Page 16: ...0020094581_01 08 10 Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions Glow worm Nottingham Road Belper Derbyshire DE56 1JT ...