Globe VA6C Manual Download Page 6

10 ·

· 11

MANUAL | VA6J&X | VS6C | VA6C | ATEX certified

MANUAL | VA6J&X | VS6C | VA6C | ATEX certified

Performance regulation

2. Air flow regulation

Air flow regulation is the best way to reduce 
the output speed without the loss of torque. 
The air flow can be regulated with a throttling 
device. By throttling, the starting torque remains 
essentially the same but the torque curve is 
steeper. This means that under the same load 
fluctuation, the speed fluctuation is smaller in 
comparison with the pressure regulation. There 
is a distinction made between the following 
installation positions:

Exhaust air throttling

The exhaust air throttling is the less optimal 
way of throttling relating to the durability 
and the air consumption. The advantage of 
this method is that the rotational speed can 
be regulated constantly in the lower rotation 
range. In the border area of the rotation range, 
a combination of supply- and exhaust air 
throttling should be used. The exhaust throttling 
should be used for controlling low speed of 
rotation.

Supply air throttling

The supply air throttling generates better 
results in relation to the durability, the running 
smoothness and the air consumption.

With the regulation of the inlet pressure and the flow rate, the performance can be adapted to the 
individual application. This is done by pressure or air flow regulation or a combination of both. 
The compressibility of the air generates a dampening effect in all ranges. This allows that the motor 
also can be started, while it is loaded. With a load reduction, the motor reacts immediately with an 
increase in speed.

0

100

120

140

160

180

200

220

240

1

2

3

4

5

6

Rotation speed

Tor

que

0

100

120

140

160

180

200

220

240

1

2

3

4

5

6

Rotation speed

Tor

que

Pressure regulation

Air flow regulation

0

100

120

140

160

180

200

220

240

1

2

3

4

5

6

Rotation speed

Tor

que

0

100

120

140

160

180

200

220

240

1

2

3

4

5

6

Rotation speed

Tor

que

Pressure regulation

Air flow regulation

For optimal power and speed control we advise to use the 

combination of pressure and air flow regulation.

Pressure regulation

Air flow regulation

(optional)

 

Supply air th

rot

tling

Exh
aust air th

rot

tling

1. Pressure regulation

With pressure regulation the output power 
can be adjusted. When the supply pressure is 
decreased, the torque and power is reduced 
proportionally and the torque curve becomes 
flatter. The forces inside the motor are also 
reduced, which increases its durability.

Maintenance

WARNING - Injury hazard

Wear eye protection: Air stream from product may contain solid or liquid materials that 
can result in eye or skin damage.

Failure to follow these instructions can result in serious injury or property damage.

Flush this product in a well ventilated area.

Do not use kerosene or other combustible solvents to flush this product.

Correct maintenance is your responsibility!

 Make sure you have the proper maintenance 

conditions.

Disconnect air supply and vent all air lines.

 

»

Please ensure that maintenance is carried out 
by certified staff. You can order your service 
kit at [email protected]

 

»

Check intake filter and silencer after the first 
100 hours of operation. 

 

»

Clean filters and lubricators and determine 
how frequently filters and lubricators should 
be checked during future operation. This will 
help the motor performances and it’ service 
life.

 

»

Do not open when explosive atmosphere is 
present. Sparks induced by tools may cause 
an explosion.

 

»

When performing maintenance on the air mo-
tor please use the rebuild instructions which 
are also enclosed in this manual. Please make 
sure the motor runs smooth after maintenance 
and check the clearances in the motor to pre-
vent problems when operating the motor.

VA6J&X

VS6C

VA6C

3.100 Running hours

5.100 Running hours

3.200 Running hours

 

»

To comply according to ATEX please change the bearings of the motor according to the table 
below:

Summary of Contents for VA6C

Page 1: ...x nl Manual GLOBE Vane Air Motor VA6J X VS6C VA6C ATEX certified II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T135 C Db GLOBE Airmotors Boerhaaveweg 9 1 1 NL 2408 AD Alphen a d Rijn Tel 31 172 426 608 info globe benelux nl ...

Page 2: ...dead or severe injuries Dangerous situation Possible consequence damage to the drive of the environment Wear hearing protection Wear eye protection Important instructions on protection against explosion Hazard Situation Possible consequences slight or mild injuries APPROVALS ATEX CERTIFICATION II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T135 C Db In which II 2G 2D Ex h IIC IIIC T4 T135 C Gb Db Ta Equipme...

Page 3: ... damage the shaft seal If the motor is built in a closed system or construction so that no dust or debris can get in contact with the output shaft the air motor can be used in any orientation If the motor is used is such way that the output shaft is in contact with explosive environment the mounting position is limited from horizontal to vertical downwards It is not allowed for the shaft to point ...

Page 4: ...articles and ISO 8473 1 2010 class 3 for water For the most efficient power and control of speed all valves and the airlines should be the same size as the air connections of the motor If the valves airlines and other con nections have a longer distance than 2m 6 feet of the motor we advise one size bigger Before final connection to the motor clean the compressed air connection with low pressure a...

Page 5: ...rnal heat that may cause motor damage The starting torque is less than the running torque The starting torque will vary depen ding on the position of the vanes in relation to the air intake port when the motor is being started During operation be aware if unfamiliar sounds or vibrations occur Stop the unit immediately and investigate the source In case that the motor is exposed to high vibrations ...

Page 6: ...ed Torque 0 100 120 140 160 180 200 220 240 1 2 3 4 5 6 Rotation speed Torque Pressure regulation Air flow regulation For optimal power and speed control we advise to use the combination of pressure and air flow regulation Pressure regulation Air flow regulation optional Supply air throttling Exhaust air throttling 1 Pressure regulation With pressure regulation the output power can be adjusted Whe...

Page 7: ...embly details All parts must be clean and it is recommended that new oilseals and blades are fitted as a matter of course Press all bearings fully home into their respective covers pressing only on the outer track to prevent damaging the bearings On V1 V2 V4 motors fit oilseal retaining circlip and a new oilseal Cs Rotor Shaft Assy Ejection ring Rear cover Bearing Bearing support V1 Motor Cs Rotor...

Page 8: ... 4 769 910 08 760 008 Cover Plate 1 09 1 Gasket 1 769 910 09 2 Gasket 1 769 910 09 3 Gasket 1 769 910 11 805 006 Screw 6 12 809 009 Cap Screw 6 14 806 024 Dowel 4 15 807 028 Bearing 1 16 807 025 Bearing 1 17 Oil Seal 1 769 910 18 O Ring 1 769 910 19 809 007 Capscrew 6 20 Gasket 1 769 910 21 811 020 Key 1 22 760 007 Seal Housing 1 769 910 V6 Seal Kit 820 025 Silencer 3 4 BSP 1 If unit is pre 1990 s...

Page 9: ...sket 1 769 910 21 81 1 020 Key 1 22 760 007 Seal Housing 1 23 Circlip 1 769 910 769 910 V6 Seal Kit 820 004 Silencer 3 4 1 LUBE FREE VS6CNL Vane Air Motor 152 mm 78 mm 40 mm 3 5 mm 10 mm 60 8 mm 200 mm 65 mm 41 mm diameter 64 mm 130 mm diameter 134 mm 72 5 mm 19 009 mm 18 996 mm diameter 21 500 mm 21 270 mm 130 000 mm 129 937 mm diameter 2 ports G 3 4 Tapped hole in shaft M6 x 15 mm 0 59 deep 4 ho...

Page 10: ... NL Nema Vane Air Motor 5 433 2 598 1 811 0 118 0 197 2 205 0 394 6 496 2 559 1 614 diameter 2 520 5 118 diameter 5 276 2 854 0 6250 0 6245 diameter 4 4988 4 4961 diameter 2 ports 3 4 NPT 4 holes 3 8 16 UNC Equispaced on 5 875 P C D Mounting spigot Key 0 187 square x 1 437 long Port A Max Overhung Force on shaft 300 N 70 lbf Axial loads should be kept to a minimum Mass 10 00 kg 22 04 lb Attitude T...

Page 11: ...lable for download on globe benelux nl Compact Piston Air Motors Pneumatic Brakes Compact Vane Air Motors Planetary Geared Vane Air Motor Specials Costum Build Radial Piston Air Motors GLOBE Airmotors Boerhaaveweg 9 1 1 NL 2408 AD Alphen a d Rijn Tel 31 172 426 608 info globe benelux nl ...

Reviews: