background image

2 ·

· 3

MANUAL | VA6J&X | VS6C | VA6C | ATEX certified

MANUAL | VA6J&X | VS6C | VA6C | ATEX certified

Congratulations with your GLOBE air motor!

This product is made with quality materials to meet the highest standards. 
This manual contains safety instructions for the use of your GLOBE air 
motor. Please read and follow all recommended instructions for a trouble-
free use.

Warranty

The GLOBE air motor is designed to operate without any problems. This is only guaranteed if the 
regulations with regards to installation, operation, maintenance and repair are observed. Problems 
occurring during the guarantee period are corrected in accordance to GLOBE Airmotors BV 
guarantee conditions. All results of unauthorized replacements and alterations are at the operator’s 
expense. In case of unauthorised opening and repair work carried out during guarantee period by 
the operator, the guarantees may become invalid.  

You can order your service kit at [email protected]. Please ensure that maintenance is carried 
out by certified staff.

Safety first

Safety is important for you and other people. For the protection of you and others, we have several 
warnings in this manual and on the product. Please always read carefully and follow the instructions.

STOP

Hazard

Possible consequences: dead or 

severe injuries

Dangerous situation

Possible consequence: damage 

to the drive of the environment

Wear hearing protection

Wear eye protection

Important instructions 

on protection against 

explosion

Hazard Situation

Possible consequences: slight or 

mild injuries

APPROVALS

ATEX CERTIFICATION

II 2G Ex h IIC T4 Gb

II 2D Ex h IIIC T135°C Db

In which:

II
2G
2D
Ex h
IIC
IIIC
T4
T135°C
Gb
Db
Ta

Equipment group II for use above ground 
Category 2G for use in Zone 1 or 2 
Category 2D for use in Zone 21 or 22
Protection by constructional safety “c” Gas
group IIC 
Dust group IIIC 
Temperature class T4 
Maximum surface temperature 135°C 
Equipment protection level Gb 
Equipment protection level Db
Ambient temperature range

Ta = - 20° + 60°C

Contents

Warranty 3
Safety first 

3

Checklist to comply to ATEX 

4

Installation

 5

Mounting to construction  

5

Air supply 

6

Operation

 8

Performance regulation 

10

Maintenance

 11

Summary of the hazards with  
protective means: 

12

Shutdown and long storage  

12

Rebuild instructions 

13

Trouble shooting 

14

Performance VA6J&X | VS6C | VA6C  15
Main dimensions VA6J&X 

16

Exploded view with spare parts list 

16

Main dimensions VS6C 

17

Exploded view with spare parts list 

17

Main dimensions VA6C 

18

Exploded view with spare parts list 

18

ATEX Certification 

19

The GLOBE vane air motors are ATEX certified 
according to the following (harmonized) 
standards:

EN-ISO80079-36:2016
EN-ISO80079-37: 016

The motors are marked with the following EX 
marking:

Summary of Contents for VA6C

Page 1: ...x nl Manual GLOBE Vane Air Motor VA6J X VS6C VA6C ATEX certified II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T135 C Db GLOBE Airmotors Boerhaaveweg 9 1 1 NL 2408 AD Alphen a d Rijn Tel 31 172 426 608 info globe benelux nl ...

Page 2: ...dead or severe injuries Dangerous situation Possible consequence damage to the drive of the environment Wear hearing protection Wear eye protection Important instructions on protection against explosion Hazard Situation Possible consequences slight or mild injuries APPROVALS ATEX CERTIFICATION II 2G Ex h IIC T4 Gb II 2D Ex h IIIC T135 C Db In which II 2G 2D Ex h IIC IIIC T4 T135 C Gb Db Ta Equipme...

Page 3: ... damage the shaft seal If the motor is built in a closed system or construction so that no dust or debris can get in contact with the output shaft the air motor can be used in any orientation If the motor is used is such way that the output shaft is in contact with explosive environment the mounting position is limited from horizontal to vertical downwards It is not allowed for the shaft to point ...

Page 4: ...articles and ISO 8473 1 2010 class 3 for water For the most efficient power and control of speed all valves and the airlines should be the same size as the air connections of the motor If the valves airlines and other con nections have a longer distance than 2m 6 feet of the motor we advise one size bigger Before final connection to the motor clean the compressed air connection with low pressure a...

Page 5: ...rnal heat that may cause motor damage The starting torque is less than the running torque The starting torque will vary depen ding on the position of the vanes in relation to the air intake port when the motor is being started During operation be aware if unfamiliar sounds or vibrations occur Stop the unit immediately and investigate the source In case that the motor is exposed to high vibrations ...

Page 6: ...ed Torque 0 100 120 140 160 180 200 220 240 1 2 3 4 5 6 Rotation speed Torque Pressure regulation Air flow regulation For optimal power and speed control we advise to use the combination of pressure and air flow regulation Pressure regulation Air flow regulation optional Supply air throttling Exhaust air throttling 1 Pressure regulation With pressure regulation the output power can be adjusted Whe...

Page 7: ...embly details All parts must be clean and it is recommended that new oilseals and blades are fitted as a matter of course Press all bearings fully home into their respective covers pressing only on the outer track to prevent damaging the bearings On V1 V2 V4 motors fit oilseal retaining circlip and a new oilseal Cs Rotor Shaft Assy Ejection ring Rear cover Bearing Bearing support V1 Motor Cs Rotor...

Page 8: ... 4 769 910 08 760 008 Cover Plate 1 09 1 Gasket 1 769 910 09 2 Gasket 1 769 910 09 3 Gasket 1 769 910 11 805 006 Screw 6 12 809 009 Cap Screw 6 14 806 024 Dowel 4 15 807 028 Bearing 1 16 807 025 Bearing 1 17 Oil Seal 1 769 910 18 O Ring 1 769 910 19 809 007 Capscrew 6 20 Gasket 1 769 910 21 811 020 Key 1 22 760 007 Seal Housing 1 769 910 V6 Seal Kit 820 025 Silencer 3 4 BSP 1 If unit is pre 1990 s...

Page 9: ...sket 1 769 910 21 81 1 020 Key 1 22 760 007 Seal Housing 1 23 Circlip 1 769 910 769 910 V6 Seal Kit 820 004 Silencer 3 4 1 LUBE FREE VS6CNL Vane Air Motor 152 mm 78 mm 40 mm 3 5 mm 10 mm 60 8 mm 200 mm 65 mm 41 mm diameter 64 mm 130 mm diameter 134 mm 72 5 mm 19 009 mm 18 996 mm diameter 21 500 mm 21 270 mm 130 000 mm 129 937 mm diameter 2 ports G 3 4 Tapped hole in shaft M6 x 15 mm 0 59 deep 4 ho...

Page 10: ... NL Nema Vane Air Motor 5 433 2 598 1 811 0 118 0 197 2 205 0 394 6 496 2 559 1 614 diameter 2 520 5 118 diameter 5 276 2 854 0 6250 0 6245 diameter 4 4988 4 4961 diameter 2 ports 3 4 NPT 4 holes 3 8 16 UNC Equispaced on 5 875 P C D Mounting spigot Key 0 187 square x 1 437 long Port A Max Overhung Force on shaft 300 N 70 lbf Axial loads should be kept to a minimum Mass 10 00 kg 22 04 lb Attitude T...

Page 11: ...lable for download on globe benelux nl Compact Piston Air Motors Pneumatic Brakes Compact Vane Air Motors Planetary Geared Vane Air Motor Specials Costum Build Radial Piston Air Motors GLOBE Airmotors Boerhaaveweg 9 1 1 NL 2408 AD Alphen a d Rijn Tel 31 172 426 608 info globe benelux nl ...

Reviews: