15. Warranty                           

This centrifuge is guaranteed for two years from the date of delivery provided that it has been operated and maintained 
properly. 

This centrifuge is guaranteed for two years from the date of delivery provided that it has been operated and maintained 
properly. 

Instances that would void the warranty include:

1. Failures caused by incorrect installation.

2. Failures caused by rough or improper handling. 

3. Failures caused by transportation or relocation after installation.

4. Failures caused by unauthorized disassembly or modification.

5. Failures caused by using non-standard spare parts or accessories and/or unauthorized modification of the rotor or 

centrifuge. 

6. Failures caused by natural disasters including fire, earthquakes, etc. (force majeure).

16. Service

To ensure safe and efficient operation of your GCC series centrifuge, it is necessary to keep the centrifuge clean and to use 
as recommended in this manual. If centrifuge has problems, do not attempt to repair it by yourself. In the unlikely event you 
require service or assistance, please contact Globe Scientific at:

E-Mail:

[email protected] 

Sales and Technical Support:

1 800-394-4562 ext. 2
1 201-599-1400
1 201-599-1406 fax

International Sales:

1 201-599-1400
[email protected]  

®

Customer Service:

1 800-394-4562 ext. 1
1 201-599-1400
1 201-599-1406 fax

Address:

Globe Scientific Inc.
400 Corporate Drive
Mahwah, New Jersey 07430
USA

Summary of Contents for GCC-E

Page 1: ...l Centrifuge Enhanced Feature Low Speed Clinical Centrifuge USER MANUAL GCC E www globescientific com IMPORTANT Carefully and completely read this user manual to ensure user safety and achieve most ef...

Page 2: ...ps 10 11 10 1 How to Open the Lid 11 11 Rotor Instructions 12 13 11 1 Rotor Structure 12 11 2 Available Rotors and Adapters 12 12 Calculating RCF 13 13 Returning and Disposal 13 13 1 Returning the Uni...

Page 3: ...ASK FOR HELP The precautions described in this User Manual are carefully developed in an attempt to cover all the possible risks However it is also important that you are alert for unexpected inciden...

Page 4: ...he service center of the warning code if displayed along with the model and serial numbers and a detailed description of the issue Vibrations are likely to damage the centrifuge Please contact our ser...

Page 5: ...uant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment gener...

Page 6: ...d installing on a slippery surface or a surface prone to vibration 2 Ideal ambient temperature is 20 C 5 C avoid placing the centrifuge in direct sunlight if the ambient temperature exceeds 30 C 3 Kee...

Page 7: ...s to start the centrifuge Press to stop if centrifuge is already running Adjustment Knob Rotate clockwise to increase parameter values Rotate counterclockwise to decrease parameter values Press to swi...

Page 8: ...sure centrifuge longevity When any tube is loaded a tube of the same type volume and weight must be added in the opposite rotor location Never intentionally run the centrifuge in an unbalanced conditi...

Page 9: ...nimum Rotate the Adjustment Knob counter clockwise to change settings from large small minimum maximum 2 Set the time Press the Select button the time value flashes in the time setting mode Rotate the...

Page 10: ...speed unit g the speed symbol will then flash into RCF value input status If no button is pressed after the speed value has flashed after 5 seconds the input mode will be shut down Rotate the Adjustme...

Page 11: ...may leak into the drive units and cause corrosion or deterioration to the bearings If the rotor chamber needs cleaning clean with cloth or sponge moistened with a neutral detergent solution Sterilize...

Page 12: ...and the operator can determine the malfunction with the alarm code below 9 Maintenance Cont 9 2 Rotor Installation 1 Installation 2 Adjustment 1 2 3 4 IMPORTANT Before locking the rotor rotate it and...

Page 13: ...operation E 06 The set parameter exceeds the Modify the set parameter Incorrect allowable range value Parameter E 10 86 Refer to service manual Contact Globe Scientific 10 1 How to Open the Lid WHEN...

Page 14: ...Dimension Adapters Maximum Radius Maximum Type Type Per Rotor L mm Required Speed rpm cm RCF g 15mL Conical 8 17 120 None 4500 11 2490 1 5 5mL 12 13 82 CC AD1 4500 9 8 2218 Vacuum CC PLUG 4 7mL 13 106...

Page 15: ...be disposed of as part of domestic waste The device belongs to group 8 medical devices and is categorized in the business to business field The icon of the crossed out trash can shows that the device...

Page 16: ...on 5 Failures caused by using non standard spare parts or accessories and or unauthorized modification of the rotor or centrifuge 6 Failures caused by natural disasters including fire earthquakes etc...

Reviews: