Revision 1.0
STINGR Users Manual
09/30/15
Revision 1.0
Subject To Change without Notice
P a g e
|
25
The following table summarizes the standby mode supply current for different modes
Operating Mode
Standby Current
Continous Tracking <= 30 minute interval
GPS Standby Mode + Standby mode supply current w/Accelerometer
Continous Tracking > 30 minute interval
Standby mode supply current w/Accelerometer
Motion Activated/Dock Tracking <= 30 minute interval
GPS Standby Mode + Standby mode supply current w/Accelerometer
Motion Activated/Dock Tracking > 30 minute interval
Standby mode supply current w/Accelerometer
Proprietary Track command format
Byte Bits
Parameter
Description
0
0 – 7
Leader
Always a value of 0xAA.
1
0 – 7
Length
0x0A (10 decimal)
2
0 – 7
Command Code. 0x34 = Initiate proprietary motion activated track.
3 -4
0 - 15
Interval
Interval in minutes between the track points. MIN
and MAX allowed TBD.
5
0 - 7
Byte 0 value
The value to transmit as byte 0
6
0 - 7
Byte 7 value
The value to transmit as byte 7.
7
0 - 7
Byte 8 value
The value to transmit as byte 8.
8-9
0 - 15
CRC
Example Command:
AA 0A 34
00 0A
AA BB CC 3C 94
Where:
Period :
0x000A (10 minute intervals)
Payload Byte 0:
0xAA
Payload Byte 7:
0xBB
Payload Byte 8:
0xCC