GLOBALSTAR PROPRIETARY AND CONFIDENTIAL INFORMATION
Use or disclosure of data contained on this sheet is subject to the restrictions in the Distribution Statements on the title page of this
document.
06/18/20
Subject to Change without Notice
P a g e | 55
Byte
Bits
Parameter
Description
0
0
– 7
Leader
Always a value of 0xAA.
1
0
– 7
Length
0x07
2
0
– 7
Command Code.
0x84 = Set minimum track rate command
3 - 4
0 - 15
Rate
Rate in minutes, MSB first
5 - 6
0
– 15
CRC
Response:
AA 05 84 <CRC>
Note, if a track mode (0x30, 0x34, or 0x35) is already active, this command will be NAKed if a value of greater than the
track already running is sent.
The purpose of this command is to allow a VAR to limit the minimum track interval that a customer might set so as to
not over-discharge the battery and solar charging system chosen for the particular application.
4.2.2.27
"Query Minimum Track Rate"
Query minimum track rate
Byte
Bits
Parameter
Description
0
0
– 7 Leader
Always a value of 0xAA.
1
0
– 7 Length
0x05
2
0
– 7 Command Code.
0x85 = “Query minimum track rate”
3 - 4
0-15
CRC
Will contain the CRC
Query minimum track rate response
Byte
Bits
Parameter
Description