Page 3: ...orrection technique which greatly improves interference immunity and advances sensitivity The coding can detect errors and automatically filter out errors and false data LD 11 fully complies with LoRa...

Page 4: ...3 2 Setup LD 11 LD 11 s component introduction is as below 1 IPEX antenna connector 2 LM 130 Module 3 Micro USB 4 Mini PCIe...

Page 5: ...rt LD 11 and set it with your mother board properly as below picture Note If your mPCIe slot has the screws please remove them first The LD 11 fits in one orientation only If it doesn t fit try revers...

Page 6: ...ved Use AT command AAT1 Reset to run the new settings 4 Use AT command AAT2 Tx 2 cnf aabbccdd to perform the interop testing The payload here is aabbccdd You could set other payload uplink to server 5...

Page 7: ...M Band EU ISM Band DevEUI 000DB533188A3572 000DB5331760356B DevAddr 188A3572 1760356B Default Key 1 ABP NwkSKey 28AED22B7E1516A609CFABF715884F3C Hexadecimal number AppSKey 1628AE2B7E15D2A6ABF7CF4F3C15...

Page 8: ...Bm Receiver Sensitivity 130dBm Current Consumption Receiving 89mA typical Transmitting 211mA typical Sleeping 65mA typical Dimension 50 x 29 x 9 mm Interface Mini PCIe USB Operation Temperature 40 C 8...

Page 9: ...All AT commands are case sensitive Command Description AAT1 UpdateFW Upgrade the LM 130 module firmware Response ok after entering the command AAT1 Save All parameters are saved Response ok after para...

Page 10: ...e to the current network This must be directly set solely for activation by personalization devices This parameter must not be set before attempting to join using over the air activation because it wi...

Page 11: ...e application identifier for the module The application identifier is a value given to the device by the network AAT2 NwkSKey parameter1 parameter1 16 byte hexadecimal number representing the network...

Page 12: ...ey Response ok if address is valid invalid_param if parameter1 is not valid This command sets the application key for the module The application key is used to identify a grouping over module units wh...

Page 13: ...ke effect when TestMode 1 Response ok if parameter1 is valid invalid_param if parameter1 is not valid This command sets the report interval for the module AAT1 EVK_TxCycle Response decimal number repr...

Page 14: ...nfirmed uplink communication when no downlink response has been received AAT2 RxDelay1 parameter1 parameter1 decimal number representing the delay between the transmission and the first reception wind...

Page 15: ...s The first response will be received immediately is valid ok reply received the second reply will be received after the end of the uplink transmission Please refer to the the LoRaWANTM Specification...

Page 16: ...cycle AAT2 PLCheck parameter1 parameter1 0 disable 1 enable Response ok if address is valid invalid_param if parameter1 is not valid This command sets the payload length s verification AAT2 PLCheck R...

Page 17: ...o 3 This command sets the index of Rx1 offset The Rx1DrOffset sets the offset between the uplink data rate and the downlink data rate used to communicate with the end device on the first reception slo...

Page 18: ...S is 0 The range for EU is from 0 to 3 Please refer to AAT2 Tx_Band parameter1 parameter2 parameter3 for further understanding Response ok if address is valid invalid_param if one of parameters is not...

Page 19: ...id This command sets duty cycle and Tx power for the assigned number of band grouping For example AAT2 Tx_Band 0 50 5 for US Description The real duty cycle 100 50 2 Modify band grouping 0 to set duty...

Page 20: ...sets the index of Tx power and the real Tx power for Tx power table AAT2 Tx_Power Response the Tx power table will be shown This command will show Tx power table AAT2 Tx_Powerx Response the real power...

Page 21: ...1 parameter2 parameter1 decimal number representing DataRate from 0 to 15 parameter2 decimal number representing maximum application payload length N from 0 to 255 Response ok if address is valid inva...