Global Power Technologies
ASSEMBLY AND INSTALLATION
302842 Rev0 | Sentinel
Page 19 of 61
For increased security, GPT offers a lockable enclosure to prevent tampering with the fuel filter
housing. GPT part number 303657.
Figure 8 – Sentinel, Fuel Filter Security Cover (Optional)
3.5
INSTALLING THE REGULATOR SUBASSEMBLY
Apply thread sealant to the nipple threads as illustrated in Figure 10 to minimize fuel line
contamination. Install the regulator subassembly to the safety shut-off valve through the opening on
the floor of the instrumentation enclosure.
3.6
CONNECTING THE FUEL FILTER TO THE TEG
Fuel to the Sentinel TEG is supplied through the fuel filter. Before connecting the fuel supply to the
fuel filter, connect the fuel filter to the TEG as follows:
1.
Bend the straight section of the supplied 1/4” tubing to suit the distance and arrangement
between the outlet of the fuel filter and the inlet to the ball valve on the TEG.
2.
Connect and swage one end of the 1/4” tubing to the manual ball valve below the fuel regulator
of the Sentinel TEG.
3.
Connect and swage the other end of the 1/4” tubing to the Swagelok connector located above
the flow arrow of the
fuel
filter.