The above levels of exposure relate to healthy adults. Levels differ for those at high risk. Exposure to high levels of carbon monoxide 
can be fatal or cause permanent damage and disabilities. Many cases of reported carbon monoxide poisoning indicate that while 
victims are aware they are not well, they become so disoriented they are unable to save themselves by either exiting the building, or 
calling for assistance. Also, young children and household pets may be the first effected. Familiarization with the effects of each level 
is important. 

WARNING!-Exposure to high levels of carbon monoxide can be fatal or cause permanent damage and disabilities. 

 

8. Specification: 

Model: 

GS819 

Type of apparatus: 

Type B

 

Power Supply: 

DC 3V(2pcs alkaline battery)

 

Recommend battery type: 

GP GN15A / Raymax LR6 

Sensor Type: 

Electrochemical 

Product life:

 10 years after initial power up 

Sensitivity Setting: 

Conforms to EN 50291-1:2010+A1:2012 standard. 

          30PPM          Without alarm before 120 minutes 
          50PPM          Between 60 to 90 minutes 
          100PPM        Between 10 to 40 minutes 
          300PPM        Less than 3 minutes 

Standby Current: 

<50µA (average)

 

Alarm Current: 

<25mA (average) 

Operation Ambient Condition:

 -10~+40℃, 30~95%RH non-condensing 

Storage/Transport Ambient Condition: 

-20~+50℃, 10~95% RHnon-condensing 

Alarm sound : 

≥85DB at 100cm @3.2±0.5KHz pulsing alarm

 

CO alarm silence: 

about 5 minutes

 

Low Battery warning silence: 

about 9 hours

 

NOTE: This CO alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect 
any other gas. 
 

9. Manufacturer and customer service information:     

NINGBO SITERWELL ELECTRONICS CO., LTD   
ADDRESS: NO.76 HAICHUAN ROAD, CHUANGYE ZONE B, JIANGBEI, NINGBO, CHINA   
TEL: 0086-574-83076656              FAX: 0086-574-83076652        E-MAIL: [email protected]   
 

11. Warranty Information 

THREE YEARS LIMITED WARRANTY 

Dear customer, 

Our  products  are  subject  to  strict  quality  controls.  However,  if  this  device  should  unexpectedly  not  function 

perfectly, please contact the customer services address given on

 

warranty service information. This is the only way for 

you to be able to return your device of have it picked up free. 
 

The warranty period is 36 months and begins on the day of purchase. 

 

Please always keep your till receipt as proof of purchase. Warranty claims can only be made for possible defects 

Summary of Contents for GS819

Page 1: ...th its operation CAUTION This CO alarm is designed for indoor use only DO not expose to rain or moisture DO not knock or drop the detector DO not open or tamper with the alarm as this could cause malfunction The alarm will not protect against the risk of carbon monoxide poisoning when the battery has drained Installation of the alarm should not be used as a substitute for proper installation use a...

Page 2: ... the screw heads are approximately 5mm from wall 3 Test the unit by using the TEST SILENCE button Ensure the unit sound is alarm pattern 4 Hook the unit over the screws onto keyholes in back of unit As you install the battery on the unit maybe it will sound for several minutes then stop and enter in normal operation mode If it always sounds please call our agent 1 3 Recommended installation locati...

Page 3: ...usty dirty or greasy areas such as kitchens garages and furnace rooms Dust grease and household chemicals can affect the sensor Keep out of damp and humid areas such as the bath room Avoid spraying aerosols near the CO alarm Do not install in areas where the temperature is below 10 or hotter than 40 Do not place behind curtains or furniture CO must be able to reach the sensor for the unit to accur...

Page 4: ... 3 Fault warning If the unit chirps once every 30 seconds with FAULT indicator yellow LED will be flash It indicates the CO alarm is in malfunction condition That means your CO alarm has no detecting function and no respond CO Replace battery if condition continues the CO alarm has malfunctioned Replace immediately Please contact us to more service 3 4 Low battery voltage warning If the alarm chir...

Page 5: ...t flashes This does not indicate that CO is present NOTE Test the unit weekly If at any time your unit does not perform as described replace it immediately NOTE The function of human alarm sounds will enable for button test Please press and hold test button more than 10 second the alarm will issuing a normal alarm volume 85dB 4 What to do if the alarm sounds WARNING Actuation of your CO alarm indi...

Page 6: ...e false actions methane propane isobutene isopropanol ethylene benzene toluene ethyl acetate hydrogen sulfide sulfur dioxides alcohol based products paints thinner solvents adhesives hair sprays after shaves perfumes and some cleaning agents WARNING Your CO alarm will not be operational and will not monitor for CO levels without battery WARNING This apparatus is designed to protect individuals fro...

Page 7: ... 40 minutes 300PPM Less than 3 minutes Standby Current 50µA average Alarm Current 25mA average Operation Ambient Condition 10 40 30 95 RH non condensing Storage Transport Ambient Condition 20 50 10 95 RHnon condensing Alarm sound 85DB at 100cm 3 2 0 5KHz pulsing alarm CO alarm silence about 5 minutes Low Battery warning silence about 9 hours NOTE This CO alarm is designed to detect carbon monoxide...

Page 8: ...d out after the warranty period must be paid for In the event of misuse or improper treatment use of force or intervention not carried out by our authorized service branches the warranty is no longer valid This warranty does not restrict your legal rights NOTE In the event of a warranty claim please return the till receipt and completed warranty card with fault description together with the defect...

Reviews: