18
POWER SUPPLY ERROR
265/140V 65Hz
Appears when the input voltage or frequency is over
265/140 Vac and 65 Hz, respectively.
POWER SUPPLY ERROR
195/90V 45Hz
Appears when the input voltage or frequency is under
195/90 Vac and 45 Hz, respectively.
Check the power supply (generator) and correct the defect. It is not necessary to switch
the unit off and switch it on again to refresh the input voltage.
3.1.5 Using the Barcode Reader:
If you read the different data (operator’s ID, job ID, fittings, pipe, etc) by using optical
means (scanner), connect the reader device into the corresponding connector and put it
in front of the barcode data.
NOTE FOR SERIAL SCANNER ONLY !
The serial scanner should be correctly setup. In case no data is captured
by the device, carry out the following barcode reading.
Software version
#
v. 1.23
Software version
$
v. 1.24
Laser scanner: When reading, the connected scanner emits a red laser line of a particular
length. To capture the barcode data, place the scanner so that the laser line coincides
longitudinally with the barcode. The distance will depend on the size of the barcode to
read. Once the scanner has been placed in position, the laser line will stop flashing and
remain fixed. When this happens, press any of the three buttons on the top of the
scanner.
Figure 8: Example of using the laser scanner
NOTE !
If none of the configuration menu options are enabled, such as
identification of the operator, job, auxiliary data or traceability, go
directly to clause 3.1.10 - Fitting connection.