![Global 716173 Quick Start Manual Download Page 18](http://html.mh-extra.com/html/global/716173/716173_quick-start-manual_2232477018.webp)
16
STORAGE
DANGER:
Fuel and vapors are extremely flammable and explosive. Store fuel in a well
ventilated area. Keep away from any sparks and fire. Failure to do so will result in death or
serious injury.
WARNING:
Verify machine has properly cooled before installing cover and storing. Hot
surfaces could result in fire.
It is recommended to start and run the generator for 30 minutes, every 30 days. If this is not
possible, refer to the following list to prepare unit for storage:
DO NOT place storage covers on a hot generator. Allow unit to cool to room temperature
before storing.
DO NOT store fuel from one season to another unless properly treated.
Replace fuel container if rust is present. Rust in fuel will cause fuel system problems.
Cover unit with a suitable protective moisture-resistant cover.
Store unit in a clean and dry area.
Always store generator and fuel away from heat and ignition sources.
PREPARE FUEL SYSTEM FOR STORAGE
Fuel stored over 30 days can go bad and damage fuel system components. Keep fuel fresh or
use a fuel stabilizer. If a fuel stabilizer is added, prepare and run engine for long term storage:
Run engine for 10-15 minutes to circulate stabilizer throughout fuel system. Adequately
prepared fuel can be stored up to 24 months.
NOTE:
If fuel has not been treated with fuel stabilizer, it must be drained into container. Check
with your local authority for fuel storage.
WARNING:
Vision Loss. Eye protection is required to avoid spray from spark plug hole when
cranking engine. Failure to do so could result in vision loss.