background image

 

Part 

Number 

Descripti

on 

Qt

AF1000

01 

Metal 

Cover 

AF1000

02 

Top 

Hepa 

Cover 

293053 

Pre Pad 

Filter 

293054 

Pre-Filte

293056 

Hepa 

Filter 

AF1000

06 

Fan 

Motor 

AF1000

07 

Handle 

AF1000

08 

Clamp 

AF1000

09 

Housing 

AF1000

10 

Wheel 

AF1000

11 

Hepa 

Filter 

Clamp 

AF1000

12 

Hepa 

Change 

Light 

AF1000

13 

Switch 

AF1000

14 

Connect

or 

AF1000

15 

Power 

Cord 

AF1000

16 

Circuit 

Breaker 

AF1000

17 

Switch 

Panel 

AF1000

Metal 

Part List 

Summary of Contents for 293052

Page 1: ...INSTRUCTION MANUAL READ ENTIRE MANUAL BEFORE USE Global Industrial 11 Harbor Park Drive Port Washington NY 11050 293052 Commercial Air Scrubber 1000cfm ...

Page 2: ...pair center Never attempt to disassemble or repair unit while air scrubber is plugged in 11 Prior to use ensure the air intake and outlet are free of obstructions to prevent the air scrubber from overheating and causing a shock or fire hazard 12 Operating Procedures The Global Industrial Air Scrubber is a portable filtration system that removes airborne particles including mold pet dander dust pol...

Page 3: ...tenance contact Global Industrial Filters The air scrubber equip the 3 stage filters including 1 pre pad filter 1 pre filter 1 optional carbon filter 1 hepa filter 1 The pre pad filter and Prefilter is used for Captures the largest particles to help extend the life of hepa Filter 2 The hepa filter is used to against oily aerosol particles down to 0 3 microns 3 The carbon filter is used to Captures...

Page 4: ...r 1 293056 Hepa Filter 1 AF1000 06 Fan Motor 1 AF1000 07 Handle 1 AF1000 08 Clamp 4 AF1000 09 Housing 1 AF1000 10 Wheel 2 AF1000 11 Hepa Filter Clamp 4 AF1000 12 Hepa Change Light 1 AF1000 13 Switch 1 AF1000 14 Connect or 1 AF1000 15 Power Cord 1 AF1000 16 Circuit Breaker 1 AF1000 17 Switch Panel 1 AF1000 Metal 1 Part List ...

Page 5: ...ributor if inside warranty period BLOWER VIBRATES 1 Motor shaft is bent Contact your distributor if inside warranty period 2 Fan blade is bent Contact your distributor if inside warranty period 3 Excessive dirt built up on fan blade Clean blade and ensure blade housing is free of dust and dirt before use BLOWER MAKES SCRAPING NOISES 1 Damaged housing Inspect housing for warps or dents If housing i...