background image

 

 

 

 

 

 

 

 

 

 

Safety Instructions 

Please observe the following safety instructions to avoid personal injury and property loss. 

1)

 

Do not operate any air scrubber with a damaged cord or Plug. 

2)

 

Do not move or adjust air scrubber while in operation 

3)

 

Keep this unit out of the reach of children 

4)

 

Do not alter or modify your air scrubber in any way. Only authorized Global Industrial replacement parts can 
be used. Use of any unauthorized parts could cause hazards and void the unit’s warranty 

5)

 

Always store unit in a clean, dry environment when not in use. Care should be taken to prevent water from 
entering the unit’s motor. In the case that the unit’s motor does become wet, ensure that the motor is dried 
thoroughly before use.       

6)

 

Do not allow water near or inside the unit while in use to avoid risk of electric shock. Handle unit with care to 

avoid causing damage or personal injury. 

7)

 

Always operate the air scrubber on a flat, level surface. Operating the unit where it could slip or fall increases 

the risk of injury, fire, or electrical shock.   

8)

 

Never operate the air scrubber without the factory-installed safety screens in place. This will prevent liquids, 

gases, and other materials from entering the air scrubber.   

9)

 

Do  not  use  air  scrubber  near  combustible  gas  or  flammable  materials  in  order  to  avoid  fire  or  electrical 

hazards. 

10)

 

Do not attempt to disassemble or repair unit on your own. Instead, bring to the attention of your distributor or 

a certified repair center. Never attempt to disassemble or repair unit while air scrubber is plugged in. 

11)

 

Prior  to  use,  ensure  the  air  intake  and  outlet  are  free  of  obstructions  to  prevent  the  air  scrubber  from 

overheating and causing a shock or fire hazard. 

12)

 

 

Operating Procedures   

The Global Industrial Air Scrubber is a portable filtration system that removes airborne particles including mold, 

pet dander, dust, pollen, drywall dust, and other miscellaneous debris as small as 0.3 microns. The air scrubber 

utilizes up to 4 stages of filtration including a Pre-pad filter, a pre-filter, optional 2nd stage, and a HEPA filter. The 

air scrubber will create cleaner air in any environment. The pre-pad filter and pre filter capture larger particles and 

the HEPA filter captures smaller particles. 

 

1)

 

Ensure that the unit is on a stable, level surface, and remains stationary while in use. 

2)

 

Plug the air scrubber into a grounded outlet with the correct voltage(115v) and amperage. Ensure that the 

unit  is  plugged  into  a  grounded  outlet  with  voltage  and  wattage  outputs  that  co

rrespond  with  the  unit’s 

specifications. For maximum protection against electrical shock, ALWAYS use a circuit that is protected by a 

ground fault circuit interrupter. If you are unsure about the outlet, check with a qualified electrician. 

Controls   

The air scrubber equip the 1 speed light led switch 

Control fan by press the switch knob 

OFF-Turn off the air scrubber 

ON- Turn on the air scrubber 

The air scrubber equip the Circuit breaker to protect the 

Motor not over load. To reset, unplug the appliance   

Causing the breaker to trip and push the reset buttom. 

Hepa 

Change Light 

Switch 

Circuit 

Breaker 

Summary of Contents for 293052

Page 1: ...INSTRUCTION MANUAL READ ENTIRE MANUAL BEFORE USE Global Industrial 11 Harbor Park Drive Port Washington NY 11050 293052 Commercial Air Scrubber 1000cfm ...

Page 2: ...pair center Never attempt to disassemble or repair unit while air scrubber is plugged in 11 Prior to use ensure the air intake and outlet are free of obstructions to prevent the air scrubber from overheating and causing a shock or fire hazard 12 Operating Procedures The Global Industrial Air Scrubber is a portable filtration system that removes airborne particles including mold pet dander dust pol...

Page 3: ...tenance contact Global Industrial Filters The air scrubber equip the 3 stage filters including 1 pre pad filter 1 pre filter 1 optional carbon filter 1 hepa filter 1 The pre pad filter and Prefilter is used for Captures the largest particles to help extend the life of hepa Filter 2 The hepa filter is used to against oily aerosol particles down to 0 3 microns 3 The carbon filter is used to Captures...

Page 4: ...r 1 293056 Hepa Filter 1 AF1000 06 Fan Motor 1 AF1000 07 Handle 1 AF1000 08 Clamp 4 AF1000 09 Housing 1 AF1000 10 Wheel 2 AF1000 11 Hepa Filter Clamp 4 AF1000 12 Hepa Change Light 1 AF1000 13 Switch 1 AF1000 14 Connect or 1 AF1000 15 Power Cord 1 AF1000 16 Circuit Breaker 1 AF1000 17 Switch Panel 1 AF1000 Metal 1 Part List ...

Page 5: ...ributor if inside warranty period BLOWER VIBRATES 1 Motor shaft is bent Contact your distributor if inside warranty period 2 Fan blade is bent Contact your distributor if inside warranty period 3 Excessive dirt built up on fan blade Clean blade and ensure blade housing is free of dust and dirt before use BLOWER MAKES SCRAPING NOISES 1 Damaged housing Inspect housing for warps or dents If housing i...