6
ASSEMBLY AND USER GUIDE
PORTABLE DEIONIZED WATER SYSTEM
BEFORE INSTALLATION
OPERATING PARAMETERS
WATER SUPPLY
Quality
Municipal Water
Max. Pressure
125 psi | 8.6 bar
Recommended Pressure
45 psi | 3 bar
Max. Flowrate
2.5 GPM / 9.5 LPM
Recommended Flowrate
1 GPM / 4.5 LPM
Temperature
5°C - 40°C / 40°F - 104°F
PLUMBING
Inlet Water Connection
3/4” Male Garden Hose Connector
Garden Hose Connection
3/4” Male Garden Hose Connector
GENERAL OPERATING REQUIREMENTS
Please use filtered water or city water.
DO NOT
use hot water with this system.
CAUTION
If the system is not being used, store the system indoors. For
storage, avoid exposure to direct sunlight and protect from
the elements. Avoid freezing to prevent damaging the system. If the system is not being
used for more than 3 weeks, relieve hose pressure, open the housings using supplied
wrench, remove cartridges and empty water from housings. Place cartridges in a
location that will not create water damage, i.e., a sink or drain. Allow cartridges to drain
completely before returning them to housings.
SYSTEM STORAGE
DO NOT
drink the water treated by this system. This water is deionized and not suitable for hu-
man consumption.
WARNING
DO NOT
use pressure washer or install pressure pump before the system.
Ensure garden hose and sprayer are purged of old water prior to installing with ZeroSpot. Old
water may contain hard minerals and may leave water spots on your car. If purging an old hose is not possible, then use a
separate garden hose and sprayer specifically for this system.
SYSTEM SETUP
Please inspect the system and components inside the box to make sure nothing is damaged during shipping.
If the system or any of the components are damaged, please stop the installation and contact Global Water
Solutions for support.