![Global Specialties PRO-50A Manual Download Page 14](http://html1.mh-extra.com/html/global-specialties/pro-50a/pro-50a_manual_2233269014.webp)
globalspecialties.com
13
10A
COM
mAhFE
TEMP
VΩHz
Diode
Figure 7. Connection for Diode Measurement
WARNING
Do not apply more than 1000 V DC across the terminals or they will
be damaged.
5. Continuity Test
Continuity is a complete path for current flow. The meter’s continuity
test is available to check for open/shorts of the circuit. The beeper
sounds if a circuit is complete. To test for continuity:
1. Set the rotary switch to the continuity range, .
2. Connect the black test lead to the COM input.
3. Connect the red test lead to the VΩHz input.
4. Connect the test leads to the resistance in the circuit being
measured.
5. When the test lead to the circuit is below 30 Ω, a
continuous beep will sound, thus indicating a closed
circuit.
10A
COM
mAhFE
TEMP
VΩHz
Continuity
Figure 8. Connection for Continuity Test