TYPICAL WIRING
Single Motor Reversing Circuit
Channels 1 and 2 Using Onboard Relays
Page 7
DIP Switch Settings
DIP SWITCH FUNCTIONS
DIP
SW
OFF
ON
1
Channel 1
Provides relay output as long as transmitter
button is pressed.
Channel 1 Relay
Provides relay pulse output for .5 seconds when
transmitter button is pressed.
2
Channel 2
Provides relay output as long as transmitter
button is pressed.
Channel 2
Provides relay pulse output for .5 seconds when
transmitter button is pressed.
3
No function.
If Channel 1, or 2 receive a signal 8 or more
times within 20 seconds channel 1 & 2 will be
deactivated for 30 seconds then reset to normal.
4
Not used.
5
Not used.
6
Channel 6
Provides (
-) 500mA output as long as trans-
mitter button is pressed.
Provides (
-) 500mA pulse output for .5 seconds
when transmitter button is pressed.
Ties channel 6 with channels 1 & 2. When either
channel 1 or 2 are activated channel 6 will also
output. Typically used as “Light Flash” if Versa7
is used as a keyless entry system.
7
Channel 7
Provides (
-) 500mA output as long as trans-
mitter button is pressed.
Provides (
-) 500mA pulse output for .05 seconds
when transmitter button is pressed.
Ties channel 7 with channels 1 & 2. When either
channel 1 or 2 are activated channel 7 will also
output. Typically used as “Horn Honk” if Versa7
is used as a keyless entry system.
8
Not used.
Refer to the table below for DIP switch settings and special functions.
The default position for all DIP switches is OFF.
Page 4