background image

6

Assembly Instructions

Wall Mounted Filtered

Water Cooler

Attach mounting bracket to wall

Note:

 To comply with ADA requirements, the base of stencil must be 

installed 11" to 14

3

/

4

" from the floor. See Rough-in Guide for additional 

ADA requirements.

Note:

 Before installing bracket to the wall, check location of power source, 

water line and drain.
•  Affix stencil with tape to appropriate wall. It is recommended to use a level 

to ensure the stencil is hung straight horizontally.

•  Drill (6) holes appropriate for the wall anchors (75 lb. minimum each) 

as indicated on the mounting bracket on the stencil. Use appropriate 

anchors for your wall type.

•  Drill (2) holes appropriate for the wall anchors (75 lb. minimum each) as 

indicated on the bottom support holes on the stencil. Use appropriate 

anchors for your wall type.

•  Remove stencil from the wall and install bracket onto the wall using 

appropriate anchors.

4

5

        CAUTION

Hanging assembled unit to wall

Carefully hang assembled unit onto the 

wall by lowering onto mounting bracket. 

       WARNING 

installation of 

equipment should be 

performed by 2 people.

6

Valve Control 

•  

Ensure water control valves are turned to the 

closed position.

•  Attach 2 screws (not included) through the frame 

of the Cooling System and into the bottom 

support holes previously drilled into the wall.

•  Connect the buildings water supply to the Filter 

Head Connection. This connection must be made 

through the back of the Cooling System.

•  Connect the internal drain line to the building's 

external drain. This connection must be made 

through the back of the Cooling System.

Closed

Closed

Connect filter head 

to water supply

Lift Points

Water control valves 

Wall mounting 

hardware not provided

Always wear work 

gloves when lifting

Level

Mounting 

Bracket

Note:

 If cooling system is on its side or back for more than 

10 minutes, allow it to stand in the upright position for 

24 hours before water connections and initial power-on. 

Summary of Contents for 761217

Page 1: ...in this manual All other services should be referred to a qualified technician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of water d...

Page 2: ...7 Pencil 8 Level Device 9 8 75 lb Capacity Flat Head Wall Anchors appropriate for your wall type 10 8 Flat Head Anchor Screws WARNING Review manual thoroughly and verify rough ins before installation...

Page 3: ...3 User s Manual Wall Mounted Filtered Water Cooler Check local codes for plumbing requirements prior to installation...

Page 4: ...Filler Access Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw Star Key remove the 4 screws at the...

Page 5: ...blue Activation Connectors B to the Solenoid Valve B Attach stainless steel pan Feed the Reset Button Connection through the Cooling System s frame and carefully lower the Stainless Steel Pan on top o...

Page 6: ...e wall using appropriate anchors 4 5 CAUTION Hanging assembled unit to wall Carefully hang assembled unit onto the wall by lowering onto mounting bracket WARNING installation of equipment should be pe...

Page 7: ...on button Connect the Reset Button connection cable to the Activation Buttons located at the top of the filter access door frame Reinstall the filter access door using the provided key Unit is now rea...

Page 8: ...Lower Cover and access the thermostat onthefronthousingframe Usingaflatheadscrewdriver turn thermostat screw clockwise to lower temperature setting Note Please allow 5 10 minutes for water temperature...

Page 9: ...s will be displayed Tap SET button 3 times to select 1500 gallon filter option 2 LED lights will be displayed Tap SET button 4 times to select NO filter option 1 LED lights will be displayed 3 Tap ENT...

Page 10: ...water drain Note Wiping the surface clean to remove debris or build up will not hurt the antimicrobial properties Maintenance Issue Possible Cause Suggested Action Water Temperature not Cool The ther...