SPECIFICATIONS

Product Standard

GB/T11883-2017

Accuracy Grade

III

Zero Range

100% Full Scale

Time to Stable 

Reading

<10 Seconds

Display Specifications

5-digit Super High Brightness 25 

mm red LED display 
Or 5-digit 20 mm FSTN LCD display 

with back lighting

Hanging Fixture

360-degree swirl safe hook & 

shackle

Operating 

Temperature

-10°C ~ +40°C

Operating Humidity

30% ~ 90% RH

Auto Power Off

30 minutes after the scale inactive 

or at extreme low power supply

Internal circuit with 

charging protection

To enhance the energy of battery 

and prolong its performing life   

Scale casing

Cast aluminum casing, corrosion 

safe, anti-static and light weight

Keypad

Light touch keypad

The keypad includes On/Off, Units, Zero, and Hold. 

(Note: The above keys can be used in sub-menu to set up lb-kg 

conversion, Hold, Beeper On/Off, Zeroing and backlighting, 

etc.)

Max. Capacity

Division Max. Capacity 

Division

6000 lb

1 lb

3000 kg

0.5 kg

10000 lb

5 lb

5000 kg

2 kg

20000 lb

10 lb

10000 kg

5 kg

KEYPAD FUNCTIONS

1. [HOLD] : Press this key to keep the current weight and there 

is a LED indication lamp on the bottom of the display window. 

Press this key again when the displaying weight flickers to 

cancel the HOLD function.

2. [UNITS] : Press this key to change units between lb and kg.

3. [ZERO] : Press this key to set the current weight to zero.

SCALE OPERATIONS

1. Turn on the Scale

Press the power switch located under the displaying window 

of scale. The scale’s maximum weighing capacity is first shown, 

and then the scale goes through a self-check sequence. 

5 seconds later, the scale will stabilize and be ready for 

operation. (Note: it is recommended to allow scale 3~5 minutes 

of warm-up time before starting weighing operation).

2. Zeroing

In default, the scale shows “0kg” or “0.0kg” after it is turned 

on.  In case the display is showing numerical value other than 

“0”, press [ZERO] on the keypad or the remote to set the 

display to “0”.

3. Weight Measurement

a) Once the load is suspended completely, the display shows 

the weight value of the load. When the “Stable” indicator is lit, 

weight value can be recorded.

b) In case there is tare such as cable, load the tare and press 

[ZERO] to zero the display to “0”kg.  The weight value after 

this will be the net weight.  This will not change until the tare 

change or the scale being turned off.

4. Turn Off the Scale

After weighing operation, press the power switch to shut off 

the power completely to prevent the leakage of the battery.