1
MODEL # 412651, 412652, 412653, 412654, 412655
User's manual
Manual del usuario
Manuel de l'utilisateur
Customer Service
US: 1-800-645-2986
Servicio de atención al Cliente
US: 1-800-645-2986
Service à la clientèle
Canada: 888-645-2986
SPECIFICATIONS
Product Standard
GB/T11883-2017
Accuracy Grade
III
Zero Range
100% Full Scale
Time to Stable
Reading
<10 Seconds
Display Specifications
5-digit Super High Brightness 25
mm red LED display
Or 5-digit 20 mm FSTN LCD display
with back lighting
Hanging Fixture
360-degree swirl safe hook &
shackle
Operating
Temperature
-10°C ~ +40°C
Operating Humidity
30% ~ 90% RH
Auto Power Off
30 minutes after the scale inactive
or at extreme low power supply
Internal circuit with
charging protection
To enhance the energy of battery
and prolong its performing life
Scale casing
Cast aluminum casing, corrosion
safe, anti-static and light weight
Keypad
Light touch keypad
The keypad includes On/Off, Units, Zero, and Hold.
(Note: The above keys can be used in sub-menu to set up lb-kg
conversion, Hold, Beeper On/Off, Zeroing and backlighting,
etc.)
Max. Capacity
Division Max. Capacity
Division
6000 lb
1 lb
3000 kg
0.5 kg
10000 lb
5 lb
5000 kg
2 kg
20000 lb
10 lb
10000 kg
5 kg
KEYPAD FUNCTIONS
1. [HOLD] : Press this key to keep the current weight and there
is a LED indication lamp on the bottom of the display window.
Press this key again when the displaying weight flickers to
cancel the HOLD function.
2. [UNITS] : Press this key to change units between lb and kg.
3. [ZERO] : Press this key to set the current weight to zero.
SCALE OPERATIONS
1. Turn on the Scale
Press the power switch located under the displaying window
of scale. The scale’s maximum weighing capacity is first shown,
and then the scale goes through a self-check sequence.
5 seconds later, the scale will stabilize and be ready for
operation. (Note: it is recommended to allow scale 3~5 minutes
of warm-up time before starting weighing operation).
2. Zeroing
In default, the scale shows “0kg” or “0.0kg” after it is turned
on. In case the display is showing numerical value other than
“0”, press [ZERO] on the keypad or the remote to set the
display to “0”.
3. Weight Measurement
a) Once the load is suspended completely, the display shows
the weight value of the load. When the “Stable” indicator is lit,
weight value can be recorded.
b) In case there is tare such as cable, load the tare and press
[ZERO] to zero the display to “0”kg. The weight value after
this will be the net weight. This will not change until the tare
change or the scale being turned off.
4. Turn Off the Scale
After weighing operation, press the power switch to shut off
the power completely to prevent the leakage of the battery.
Models: 412651, 412652, 412653, 412654, 412655