OPERATION

The air scrubber is a portable filtration system that draws
air in from the surrounding environment and passes it
through an advanced filtration system. The unit
removes airborne particles like dust, mold spores, pollen,
pet dander and miscellaneous debris.
It uses an efficient mix of airflow and filtration to create
“cleaner” air. The unit’s maximum 500 CFM motor draws
air into three types of filters--a pre-filter and a activated
carbon filter and a HEPA filter. The first stage of
filtration captures larger particles,the second stage of
effectively wipe off the toxicant and the third stage of
filtration captures much smaller particles down to 0.3
microns and larger, such as mold spores and fungi.
You can use the air scrubber for mold remediation or
water damage restoration

STORING THE UNIT

The handle of one unit fits into
bottom of another unit.
You can also stack them
horizontally for spacesaving
storage, or operate a unit with
its outlet facing upward.

NOTE:
When stacking units,beware of tipping.
Do not stack more than 3 units on top
of each other.Falling equipment
could cause bodily harm.

Filter Maintenance

The air scrubber utilizes a 3-stage filtration system designed
with the most advanced HEPA filtration technology available.
Please replace HEPA filter when the change filter indicator
light comes on.
Inspect pre-filter before each use. Look for accumulated
dust and dirt that could restrict airflow through the filter
into the unit. If any is visible,replace out the pre-filter.
For environments with a high volume of aerosolized
particles, you can often replace dirt prefilter to extend the
life of the HEPA filter.
Replace filter procedures should be performed as follows:
1. loosen the 4 latches to take apart front housing
2. Remove used dirty filters and replace.

CONTROL PANEL

VARIABLE SPEED:
It control fan motor speed and
unit ON/OFF.
Maximum seting to 500CFM
AMPS/TIME:
Press

keys, The PCB can switched display motor

actual running current and total running time.
CHANGE HEPA FILTER:
The change light illuminates when you need to change the
HEPA filter.
CIRCUIT BREAKER:
The primary purpose of the circuit breaker is to protect the
machine. It turns the unit off when more than 12 amps run
through the on-unit circuit.
Ground Fault Circuit Interrupter (GFCI):
The GFCI helps protect the user should it detect a sudden
“ground fault”, the GFCI will interrupt the electric current. The
GFCI will also trip when a short circuit or an overload occurs.
When the GFCI “trips”, unplug the unit, and look for potential
hazards standing water, frayed cords, etc.
anything that would cause a surge of electrical current.
Relocate the unit and plug it into a different outlet.
Then push the “reset” button, andcheck to see if it

s

operating; if so, continue use, if not contact your local
distributor.

Daisy-chain Capability

Our designed the air scrubber for optimal versatility.
You can interconnect up to three units to create a
maximum of 500, 1000, or 1500 CFM using the auxiliary
outlet on the unit

s control panel.

Link up to 3 units on 1 power outlet.

TROUBLE SHOOTING

FAULT

CAUSE

SOLUTION

Unit does

not

operate

• No power to machine

• Switch not turned on

• No power to outlet

• GFCI Tripped

• Plug in the unit;

check power at outlet

• Turn on the switch

• Reset circuit

breaker/GFCI

Change

light

illuminated

• Primary filter is full

• Air intake restricted

• Replace the filters;

Refer to Maintenance

section

• Eliminate

bends/kinks in

ducting, or remove

ducting

Blower

wheel not

turning

• Obstructed blower

• Loosen blower wheel

set screw

• Remove obstruction

• Tighten set screw

WARNING:

DO NOT attempt to rectify faults using unqualified personnel.If

the problem you are experiencing is not listed here, contact

Global Industrial customer service.