7
NOTE: Full wattage heater can be converted to half wattage by removing the red jumper
wire connecting the top and bottom element terminals in the field or at the factory.
MAINTENANCE AND OPERATION
1.
Heater must be properly installed before operation.
2.
Rotate thermostat knob fully clockwise to reach the maximum heat setting.
3.
Wait at least 2 minutes, the fan control will not allow the fan to run until the
heating element is warm.
4.
If fan does not come on after extended period of time, check to see if heating
element is on and check wiring.
5.
Allow heater to continue operating until desired room temperature is reached,
then turn thermostat knob counterclockwise until thermostat clicks off. The fan
will continue operating until the element cools.
6.
Readjust thermostat settings until room remains comfortable temperature.
Turning the thermostat clockwise will increase the duration of heat production
while turning it counterclockwise will decrease the duration.
NOTE: It is advised to leave the thermostat fully clockwise when heating room from
cold temperatures.
CAUTION: Operation of the manual reset safety thermal limit control is an indication that the
heater has been subjected to some abnormal condition, It is recommended that the heater
be checked by a reputable electrician or repair service to ensure the heater has not been
damaged.