background image

WALL THERMOSTAT

Model: 246110

READ CAREFULLY

These instructions will help prevent difficul-

ties that might arise during thermostat installation.Studying the instruc-

tions first may save considerable time and money later.Observing the

following procedures will keep installation time to a minimum.Save these

instructions for future use.

READ ALL WIRE SIZING, VOLTAGE RE-

QUIREMENTS AND SAFETY DATA TO

AVOID PROPERTY DAMAGE AND PER-

SONAL INJURY OR ELECTRIC SHOCK.

READ AND SAVE THESE INSTRUCTIONS

L1 from 

power supply

Neutral from 

power supply

Line
Red

Load 
Black

Thermostat

Wire Connector

Heater

Double Pole Thermostat Installation

1.

Disconnect power supply to prevent electrical shock or 

damage to product.

2.

Run line voltage wiring to the thermostat location.

3.a)

Connect the LOAD BLACK wire from the thermostat to 

the one of wires from the heating unit.

b)

Connect another black wire from the thermostat to 

another wire from the heating unit.

4.a)

Connect the LINE RED wire on the thermostat to the 

L1 line from the supply panel.

b)

Connect another red wire from the thermostat to 

another wire from the supply panel.

5.

Make sure all connections are tight.

6. 

Insert wires into the junction box, making sure not to 

damage wiring.

7.

Secure the ground wire to the ground screw provided in 

junction box.

8.

Remove the thermostat cover by grabbing the cover from

the sides and pulling it away from base.

9.

Mount the thermostat into the junction box and secure 

using the provided screws.

10.

Replace thermostat cover.

The installation of the thermostat must comply with the ap-

plicable local and/or national electrical code and utility re-

quirements. This installation should be performed by a

qualified electrician where required by law. Ensure that all

wiring connections to the thermostat are correct and tight to

prevent electrical shorts. Use the appropriate wire to meet

local and national electrical codes for rated power consump-

tion.

Product Setup and Settings

To adjust the temperature to your requirements, turn the dial

on the thermostat clockwise all the way to turn heater on.

When the room reaches the desired temperature, turn the

thermostat knob counter clockwise until you hear the click.

Leave in this position to maintain the room temperature at

this setting. For additional heat, turn clockwise until you

hear the click and the heater will turn on.

- Turning knob fully counter clockwise will disconnect the

power to the heater.

Changing °C and °F control dials.

Use a small flathead screwdriver to pry off the control dial.

Insert into one of the slots on the dial and gentle apply pres-

sure to remove.To install the new control  dial, line up the

pins on the dial with the holes on the thermostat knob. Push

together until secured into place.

Specifications:

Thermostat is compatible with electric heaters and electric

garage heaters

Power Supply AC 120V / 208V / 240V / 277V Maximum

Power:

3360W @ 120VAC (28A)

5824W @ 208VAC (28A)

6720W @ 240VAC (28A)

7756W @ 277VAC (28A)

Sensing Element: Bimetal Temperature Operating Range:

41°F-90°F (5°C -32°C)

cETLus listing.

Functions And Features

• 120/208/240/277 Volts

•Includes both ºC and ºF control dials

•Wall mount design– Sits flush against wall

•Double Pole – provides positive OFF position

•Disconnects power for extra protection

•Large knob allows easy adjustment to all temperatures

•90°F (32°C) maximum setting

Installation Instructions

Cover

Screw

Index Plate

Base

Outlet Box

Warning: 

Turn OFF the power at the circuit breaker before

installing. Installation should be performed by a qualified

electrician.

Refer to thermostat and heater load specifications before

installation of the thermostat to see if it can handle the

amp load. The maximum this thermostat can run is 7756

Watts at 277 Volts, 6720 Watts at 240 Volts, 5824 Watts at

208 Volts and 3360 Watts at 120 Volts.

Install unit in a grounded metal or plastic wall junction box,

indoors 4 ½’ to 5’ above the floor. Avoid any area where it

can come in to contact with external sources of heat and

cold. This includes plumbing pipes, direct sunlight, a T.V.

set, lamps, and drafts from a door or window, as this may

cause inaccurate temperature readings. The most conven-

ient place is above the light switch. Not for outdoor use.

Reviews: