background image

30

Η πέργκολα είναι έτοιμη για λειτουργία.

    Κ

 

!

ΑΛΗ ΕΠΙΤΥΧΙΑ

The pergola is ready for operation

  

 

 

GOOD LUCK

  

PG120P

Installation Manual

Εγχειρίδιο εγκατάστασης

VERSION  05/2019

Summary of Contents for Alumil SMARTIA PG120P

Page 1: ...PG120P VERSION 05 2019 Installation Manual PG120P by INSTALLATION MANUAL...

Page 2: ...PG120P Installation Manual VERSION 05 2019...

Page 3: ...PG120PBase4L PG120PBase4L PG120P Installation Manual VERSION 05 2019 INSTALLATION MANUAL...

Page 4: ...work properly The hook support in mullion 435 57005 00 must be at the internal side Be carefultheoverflowguttercovertobeatitsrightplace ATTENTION Placetherestofthemullionswhilewatchingthehooksupport 4...

Page 5: ...nt application use is recommended to connection points Place one 1 width transom and screw it with two screws 798 32263 32 6 3x32mm in every side For better sealing results sealant for joint applicati...

Page 6: ...in every side For better sealing results sealant for joint application is recommended to connection points Screw the mullions tightly with drilling screws 798 32263 32 Placethesecondprojectiontransom...

Page 7: ...58550 00 A 5850 L 435 58550 00 glue AL5850 5852 3_7 7 Remove the louver holder cup M5852 Add and attach glue the plastic louver holder 435 58550 00 to each slot of the AL5850 profile PG120P Installat...

Page 8: ...sults sealant for joint use is recommended to connection of first and last profile M5757 with the width transom 8 Install the first fixed louver from the motor side and screw it on to the fixed louver...

Page 9: ...base 435 58600 00 with four 4 screws 798 41263 32 6 3x62mm When installing the louvers must be kept the correct direction of opening the pergolas louvers orientation Placetherestofthelouverswith90oinc...

Page 10: ...3_10 10 5852 190mm 798 412 5860 63 50 6 3x50 AL5851 8 5860 435 58530 00 798 32242 13 4 2x13mm Connect the louvers to each other with the AL5851 movement rod and screw it with M8 nuts Pinch the decorat...

Page 11: ...0V AC 50Hz Grey Blue Black Brown Phase Neutral Direction 1 Direction 2 V AC 230 1 _11 2_11 11 During the movement check that the terminal limits of the louvers are not exceeded and be ready to stop it...

Page 12: ...58 778 00 The pergola is ready for operation GOOD LUCK 435 58 778 00 PG120P Installation Manual VERSION 05 2019 my 10 15 The pergolas louvers have been programmed to open to favorite position my in 1...

Page 13: ...PG120PBase2L PG120PBase2L PG120P Installation Manual VERSION 05 2019 INSTALLATION MANUAL...

Page 14: ...TION W The width of the construction is ALWAYS parallel to the length of the louver PG120P Installation Manual VERSION 05 2019 5850 Place the wall mounted transom M5850 at the specified starting point...

Page 15: ...he wall and the wall mountedtransom Untilthetransomshavebeenplaced themullionsshouldnotscrewtightly 435 57005 00 Lazer 6_15 Place the wall mounted transom support corner SOL924 1pcs 1m by aligning it...

Page 16: ...ews798 32263 32 6 3x32mm on each side and with six 6 screws 798 41263 50 6 3x50 the corner connector 435 58 850 00 For better sealingresults sealantforjointapplicationuseisrecommendedtoconnectionpoint...

Page 17: ...htransomandfixitwithtwoscrews798 32263 32 6 3x32mm oneachside Screwthemullionstightlywithdrillingscrews Forbetter sealingresults sealantjointapplication useisrecommendedtoconnectionpoints 1_ 5 1 PG120...

Page 18: ...up to 1 11 9913 9010 9914 9010 5850 9913 Place the wall mounted profile M9913 M9010 above and M9914 M9010 bellow of wall mounted transom M5850 For better sealing results sealant joint application use...

Page 19: ...PG120PBaseTL PG120PBaseTL PG120P Installation Manual VERSION 05 2019 INSTALLATION MANUAL...

Page 20: ...el to the length of the louver Place the width transom treated at the right spot and screw it with two screws 798 32263 32 6 3x32mm on each side For better sealing results sealant for joint applicatio...

Page 21: ...3x32mm oneachside For better sealing results sealant joint application use is recommended to connection points Place the second width transom with the same way For better sealing results sealant for j...

Page 22: ...r better sealing results sealantjointapplicationuseisrecommendedtoconnectionpoints 22 798 32263 32 6 3 32 x mm Place the intermediate transom at the designated point For better sealing results sealant...

Page 23: ...follow the steps from 1 6 up to 1 11 1 _23 2_23 23 Screw the mullions tightly with drilling screws 1_6 1_11 PG120P Installation Manual VERSION 05 2019 Screw the secondary connector to transom 435 58 7...

Page 24: ...24 The pergola is ready for operation GOOD LUCK PG120P Installation Manual VERSION 05 2019...

Page 25: ...PG120PBaseTLC PG120PBaseT C L PG120P Installation Manual VERSION 05 2019 INSTALLATION MANUAL...

Page 26: ...l the over flow gutter covertobeatitsrightplace Untilthetransomsbeplaced themullionsshouldnotscrewtightly ATTENTION W The width of the construction is ALWAYS parallel to the length of the louver 2_26...

Page 27: ...width transom and screw it with two screws 798 32263 32 6 3x32mm on each side 1 _27 2_27 Place the second width transom with the same way For better sealing results sealant for joint appli cation use...

Page 28: ...e is recom mended to connection points Place the next two width transoms and screw them with two screws 798 32263 32 6 3x32mm on each side separately For better sealing results sealant for joint appli...

Page 29: ...32 6 3x32mm on each side For better sealing results sealant joint application use is recommended to connection points 1_6 1_11 29 798 32263 32 6 3x32mm Screw the mullions tightly with drilling screws...

Page 30: ...30 The pergola is ready for operation GOOD LUCK PG120P Installation Manual VERSION 05 2019...

Reviews: