Radio Control Wiring

In order to operate the door with a wireless remote, an independent 

Radio Control Unit 

may be installed and 

connected to the Glidermatic control unit.

Always disconnect power to unit BEFORE making any setting changes.

CAUTION:

Glidermatic™

Commercial Door Operator

User Manual

11

Gr

ound

+V

Single

STOP

DOWN

UP

It is essential that a supplementary safety device such as a 

Sensing Edge or Photo Electric Cell

 be 

fi tted when radio control unit is installed to prevent injury or entrapment 

Power to the receiver is supplied from terminals 

5

 

of 

J3

is

 +v, 6 

is

 ground

Ensure Jumper 

JP2

 is confi gured to match 

required voltage of 

radio control receiver

. (5, 

12 or 24VDC) 

Single (Up/Down) Output Type Receiver

Connect output of receiver to terminal 

of

 J3

Open/Close/Stop Type

 

Receiver

Connect terminals Up, Down and 

Stop of Radio Control Receiver to 

1, 2

 & 

3

 respectively

Ensure the jumper 

JP4

 Latch terminal is set to 

ON

Edge 

jumper 

JP3 

is set to 

N/O or N/C

Pcell

 jumper 

JP3 

is set to 

N/O or N/C

In accordance with the instructions supplied by the 

manufacturer of the supplementary safety system

Once any radio receiver unit is connected the unit will not operate unless a supplementary safety device is 

fi tted and the jumpers at 

JP3

 and 

JP5

 set accordingly. Refer to pages 9 and 10.

www.garagedoorsonline.co.uk

01926 463888

Summary of Contents for Glidermatic

Page 1: ...Glidermatic Commercial Door Operator Opening doors around the world www garagedoorsonline co uk 01926 463888...

Page 2: ...utomatic Close function or Radio Transmitters are being used a Sensing Edge or Photo Electric Cell must be correctly fitted and tested on a regular basis If SAFETY features do not operate correctly DI...

Page 3: ...the DRIVE UNIT and CONTROL UNIT not the installation of the door Exploded Parts Diagram 1 Drive unit 1 2 HP DC motor s 2 Gear Heads 3 Planetary gear housing 4 Drum wheel 5 Open and close limit switche...

Page 4: ...ential that the CONTROL UNIT be securely attached to the wall or structure involved through the mounting holes provided Connect the CONTROL UNIT to a 240 volt single phase AC 5 0 AMP power source bein...

Page 5: ...ever all units as standard factory issue are configured to Right Hand operation If required the handing of the operator may be changed by setting jumper JP6 1 Set jumper JP6 according to whether the o...

Page 6: ...roken springs may allow the door to fall rapidly causing severe injury or even death In all cases stand clear of the door In the event that the door appears to fall a qualified service technician will...

Page 7: ...pening height manually raise the door to the desired open position ensure the bottom bar is short of contacting the head stop observing the direction of rotation of the outer cam Rotate the outer cam...

Page 8: ...se the unit will not operate unless a supplementary safety device is fitted and the jumpers at JP3 and JP5 set accordingly Refer to pages 9 and 10 Glidermatic Commercial Door Operator User Manual 7 DO...

Page 9: ...erate discontinue use and contact a qualified service technician Glidermatic Commercial Door Operator User Manual 8 Torque Setting The Glidermatic operator is designed to stop and reverse downward ope...

Page 10: ...erminals 5 6 of J3 Ensure jumper JP2 is configured to match required voltage of photo electric cell Refer to page 11 Glidermatic Commercial Door Operator User Manual 9 Connect the two wires from the P...

Page 11: ...2 or 24 VDC power may be sourced from terminals 5 6 of J3 Ensure jumper JP2 is configured to match required voltage of sensing edge Refer to page 11 Glidermatic Commercial Door Operator User Manual 10...

Page 12: ...is v 6 is ground Ensure Jumper JP2 is configured to match required voltage of radio control receiver 5 12 or 24VDC Single Up Down Output Type Receiver Connect output of receiver to terminal 4 of J3 Op...

Page 13: ...The Glidermatic operator can be configured to automatically close the door after a prescribed period of time up to 12 minutes Enable Automatic Close JP4 To enable the Automatic Close Function move Ju...

Page 14: ...power to unit BEFORE making any setting changes CAUTION Consult the installation instructions supplied by the manufacturer of the alarm being used for connection and relay details Alarm Wiring A 5 vol...

Reviews: