AC PUMPS

Industrial grade pumps for the residential
market

The  Pro  Series  line  of  AC  sump  pumps  and
sewage  pumps  are  strong,  dependable,  and  so
energy efficient they could pay for themselves in
a few years.  The sump pumps are equipped with
dual  float  switches  for  added  reliability,  and  a
controller that will sound an alarm if there is an
AC power loss or a pump problem.  The control
unit has a terminal which can be connected to
your security system or an auto dialer to forward
the signal to you or your alarm company.  When
your main AC pump needs replacement, consider
upgrading to one of the pumps in the PHCC Pro
Series line.

FLOAT SWITCHES

What’s the most common reason your main
AC pump fails?

It’s probably the result of a float switch that is
stuck  or  broken.    Replace  it  with  a  PHCC  Pro
Series  dual  float  and  controller  for  reliable
operation.  The dual float has, not one, but two
floats mounted within a protective cage.  Should
one  float  fail  to  operate,  the  second  float
automatically  activates  the  pump.    The
protective  cage  prevents  debris  or  other  wires
from interfering with the movement of the float.
It can be used to replace the float on most AC
pumps.

CHECK VALVES

What’s a Klunkless Check Valve™?

If  you’ve  spent  any  time  in  your  basement,
you’ve probably noticed your sump pump turning
on and off with a loud clunk.  That’s the result
of the water pressure slamming the valve closed
in  the  check  valve.    The  Klunkless  Check  Valve
has  a  built-in  air  chamber  to  counteract  that
pressure and muffle the sound.  It works just like
a conventional check valve, only quieter.

WATER ALARMS

Minimize the risk of water damage

You can detect leaks before they become bigger
problems  by  placing  a  water  alarm  wherever
there  is  a  risk  of  water  damage…in  the  utility
room,  laundry  room,  kitchen,  bathroom  or
basement.  The alarm will sound when as little
as 1/32” of water reaches the sensor.

S3033

DFC1

DFC2

CCV1

PWA

Summary of Contents for PHCC 2400 Pro Series

Page 1: ...ction to existing discharge for narrow sumps 7 Battery Instructions 8 9 Control Unit Connections Positioning the float switch 9 Connecting the pump 9 Installing the battery fluid sensor 10 Connecting...

Page 2: ...ntronics Inc 645 Heathrow Drive Lincolnshire IL 60069 4205 BATTERY PREPARATION Sulfuric acid can cause blindness or severe burns Avoid contact with skin eyes or clothing In the event of an accident fl...

Page 3: ...battery with this system It will not run the pump as long as the Pro Series 2200 or B12 90 battery The internal construction of some wet cell batteries may not be compatible with this system Glentron...

Page 4: ...e main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so the backup pump and the main pump do not touch each other Select the installation method that...

Page 5: ...ia the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outsi...

Page 6: ...lled at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1...

Page 7: ...he details of each installation will vary Using sound plumbing practices route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping cap...

Page 8: ...attached to the Pro Series pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pip...

Page 9: ...OLLOW THE INSTRUCTIONS ON THIS PAGE IF THE TOP OF YOUR BATTERY LOOKS LIKE PHOTO B ON PAGE 9 FOLLOW THE INSTRUCTIONS ON PAGE 9 TO FILL THE BATTERY 1 Remove the cover of the battery box by pushing in th...

Page 10: ...erstanding the Warnings Alarms section of this manual page 11 1 The fluid in the battery is low If you are not using a PHCC Pro Series standby battery you cannot use the battery fluid sensor You will...

Page 11: ...ITIVE post Replace the wing nuts and tighten them Slide the switch on the front of the controller to the type of battery used with the system maintenance free battery or non maintenance free battery 6...

Page 12: ...let is bad When the problem is corrected the battery should recharge If the 5th light on the controller is also on check your main pump for failure The backup pump may have been activated repeatedly i...

Page 13: ...ing a surge protector 10 If any of the alarms are sounding press the RED button on the front of the control panel for one 1 second REPLACING THE BATTERY Risk of electrical shock or battery explosion w...

Page 14: ...se box for failure and correct the problem 2 Check the power cord Make sure it is securely plugged into the wall outlet Make sure the outlet is working properly 3 The control unit may have received a...

Page 15: ...n AC pump when installing the backup pump to avoid electric shock Failure to do so could cause serious injury or death Review the safety instructions on page 1 REFER TO PHOTOS AT RIGHT 1 Unplug the Pr...

Page 16: ...inal next to the screw marked common Turn the screw a few turns to lock in the wire If the security system requires a closing of a contact to activate the alarm secure the other wire in the terminal h...

Page 17: ...ated brown outs Otherwise reduce the number of other appliances on the circuit Make sure the pump is securely plugged into the back of the control unit Remove strainer from pump and clean out any debr...

Page 18: ...ted below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost or value of d...

Page 19: ...and controller for reliable operation The dual float has not one but two floats mounted within a protective cage Should one float fail to operate the second float automatically activates the pump The...

Page 20: ...2013 Glentronics Inc 1806114 05 17...