                                                        AP72-01   Page  7                                        Issue 6

RESULT CODES

When a command is issued, the GSGC6 responds with a result code (either OK or

ERROR) to indicate whether it understands and can act on the instructions.  Result Codes also
report the progress of a connection.

Word

Meaning

OK

Command executed

CONNECT
CONNECT B1

Connect

CONNECT B2

Connect

RING

Ring signal detected

NO CARRIER

Carrier lost or never detected

ERROR

Invalid command entered

BUSY

No available channel

DTMF 'n'

DTMF received

FRAMED

Codec frame found

SEARCH

Codec searching for frame

NVRAM ERROR

Error in reading or writing to Non-Volatile memory

UNKNOWN

Codec Mode not known

G722

Codec Mode = G722

MPEG

Codec Mode = MPEG

APTX

Codec Mode = APTX

0k

Sample frequency not known

16k

Sample Frequency = 16KHz

24k

Sample Frequency = 24KHz

32k

Sample Frequency = 32KHz

48k

Sample Frequency = 48KHz

56k

Data Rate = 56KBits/Sec

64k

Data Rate = 64KBits/Sec

S REGISTERS

The S registers are used to store various operating characteristics of the Terminal

Adaptor.  The following registers can be modified if necessary.  To modify the contents of the
S registers, use the ATSn=m command where n is the register number and m is the new
decimal value.  To view the contents of an S register, use the ATSn? command where n is the S
register number.

S0

         Answer On Ring Number

Default:

0

Range:

0-255

Register S0 is set to the number of rings that the Terminal Adaptor should wait before

answering.  Setting this register to 0 will disable the auto answer function.

Summary of Contents for ISDN GSGC6

Page 1: ...G GLENSOUND ELECTRONICS LTD Tel 44 0 1622 753020 6 BROOKS PLACE MAIDSTONE KENT ME14 1HE ENGLAND 44 0 1622 752662 Visit our Website at www glensound co uk Fax 44 0 1622 762330...

Page 2: ...CT DETAILS GENERAL Pink Sheets Approvals AP72 02 General Information AP72 03 GSGC6 White Sheets Front Rear Views A2 12822 Block Diagram A3 12821 Installation AP72 04 Audio I P O P Circuit Diagram A2 1...

Page 3: ...tion to the Integrated Services Digital Network ISDN The following approval number has been given to this product NS 3010 5 P 603977 ___________________________________________________________________...

Page 4: ...t 2 Either number will be automatically dialled if the corresponding DC loop is made on a rear panel connector Second it is possible to remote control it from a computer terminal using the 2 off RS232...

Page 5: ......

Page 6: ......

Page 7: ...tical frame locking It is therefore good practise to ensure that the levels sent to the GSGC6 do not exceed 14dBu CONTROL Control of the GSGC6 can be from a computer system or from our dedicated contr...

Page 8: ......

Page 9: ......

Page 10: ...med Pins 7 14 O P LOOP Codec Framed Pins 8 15 O P LOOP TA Locked 6 D9S RS232 Control Port 1 IBM PC Std Printed Down GSJ78 Pin 1 Carrier Detect o p Pin 2 Receive Data o p Pin 3 Transmit Data i p Pin 4...

Page 11: ...Aux Data Port 1 NOT FITTED Pin 1 Not Used Pin 2 Rx Data from Decoder Pin 3 Tx Data to Encoder Pin 4 Not Used Pin 5 Ground Pin 6 Not Used Pin 7 Not Used Pin 8 Not Used Pin 9 Not Used 11 00 D15P X21 Por...

Page 12: ...example would be ATS0 1 W which will switch auto answer on and then store this set up as user default 0 Note that the Z reset command should only be used in at the end of a command string as this com...

Page 13: ...connected a connect message will be displayed If a connection is not achieved then the NO CARRIER message will be returned ATD Dial ATD causes the Terminal Adaptor to dial a number according to the di...

Page 14: ...meters r n r ATS is used to set or read the Terminal Adaptor s registers Setting a register requires two parameters r which is the register to set and n which is the value to set the register to A reg...

Page 15: ...at present must be 0 The nnnnnnnnnn parameter is the telephone number to store See the ATDS n command for details of how to dial a stored number Example AT Z0 0815436417 This will store the number 081...

Page 16: ...Send G722 16KHz Fixed 1 Send MPEG Follow decode sample Freq 2 16KHz 6 24KHz 10 32KHz 14 48KHz 18 Send APTX 16KHz Fixed 3 To set the data rate to 56KBits Sec ADD 32 to the parameters in the table In t...

Page 17: ...ADSn determines what DTMF code is sent when the external loop is closed ADT Time Duration for sending DTMF Parameters 0 255 ADTn sets the period of time that DTMF is sent when the external loop is cl...

Page 18: ...ode G722 MPEG Codec Mode MPEG APTX Codec Mode APTX 0k Sample frequency not known 16k Sample Frequency 16KHz 24k Sample Frequency 24KHz 32k Sample Frequency 32KHz 48k Sample Frequency 48KHz 56k Data Ra...

Page 19: ...y S22 1 Space paritynot compatible with AD commands S23 2 Odd parity S24 3 Even parity S24 4 Mark paritynot compatible with AD commands S23 Asynchronous Data Rate Default 5 Range 1 6 S23 1 600bps S23...

Page 20: ...ters When a string is configured into this register any string presented in an incoming call with a Called Party Sub address information element present will be checked against this string This will b...

Page 21: ...Incoming calling party number This will contain the Number of the calling party CLI for the last call received This will only be so if the network passed the information across with the incoming call...

Page 22: ...41 temporary failure 47 resources unavailable 42 switching equipment congestion 49 quality of service unavailable 50 requested facility not subscribed 57 bearer capability not authorised 58 bearer ca...

Page 23: ...hat will be checked If the check fails the call will be ignored otherwise the call will be passed to the nest filtering section This is primarily of use when the ISDN connection has two directory numb...

Page 24: ...es correctly with ISDN2 circuits which meet any one of the following specifications ETSI Euro ISDN Net 3 BTNR 191 I 420 CODECS Any 2 of 4 Different codecs can be fitted in this subrack These are 1 G72...

Page 25: ...codec fitted in the GSGC6 subrack then the circuits can be used entirely independently INSTALLATION It is necessary to connect this unit to our GSGC6 subrack Connectors are 9 pin Ds The GSGC6 has fix...

Page 26: ......

Page 27: ...son the call is not successful the display will show the reason for failure A list of possible responses is shown later MAKING SWITCH56 CALLS Only available with our G722 or MPEG G722 Codecs Normally...

Page 28: ...it should dial as an ISDN64 call or as a SWITCH56 Each number can also have stored with it the codec encode mode required along with the sample rate required Press MEMORY and use the and keys to locat...

Page 29: ...te and the data rate This is simply done by pressing the Grey key 1 2 or 3 times If pressed once the encode algorithm can be changed If pressed twice the sample rate can be changed and if pressed thre...

Page 30: ...e SAMPLE RATEForces the Encoder sample rate DATA RATEMake call at 56 64 KBits Sec data rate DTMF DURATIONSpecified in hundredths of a second duration of each DTMF digit DTMF DC LOOPSpecifies DTMF code...

Page 31: ...not subscribed 3No route to destination 57Bearer capability not authorised 4Channel unacceptable BT only 58Bearer capability not available 6Channel unacceptable 63Service or option not available 7Call...

Reviews: