I N S T A L L A T I O N A N D M A I N T E N A N C E M A N U A L
T s u n a m i
F A M I L Y
F A S T E T H E R N E T W I R E L E S S B R I D G E S
J U N E 1 9 9 9
SECTION 2: PRODUCT DESCRIPTION
PAGE 2-15
AUXILIARY CONNECTIONS
There are 6 auxiliary data connections for
Tsunami
as shown in Figure 2-3.
VF
This connector is used to link two
Tsunami
radios at a repeater site for Orderwire
operation. This would allow orderwire "telephone" calls to and from any point in the
Tsunami
network.
The Tsunami orderwire circuit can also be connected to other existing
orderwire networks. See Section 3.14.1 for details.
ALARM
This connector is used for monitoring alarms electrically. The Form C relays can be
connected to other transmission equipment for monitoring alarm status locally or
remotely.
CONFIG
This is a serial interface port (RS-232 to the
Tsunami
radio. This port provides
configuration and maintenance information about the
Tsunami
radio(s) to a
connected computer or terminal.
AUX
DATA
This is a serial interface port (RS-232,
≤
9600 baud) which allows the user to connect
auxiliary serial data from one point in the radio network to another. It can be used for
separate data connection for serial devices.
10BaseT
NMS
This is an Ethernet connection for access to the Tsunami NMS (SNMP/HTML).
T1
This is a wayside data channel for T1 (DS-1) interface of auxiliary
traffic.