050-352 Product Brief
PCB Mount Transceiver
10 Mbps
– 200 Mbps, SMF, 3.3V
F
IGURE
4
R
ECOMMENDED
H
OST
B
OARD
P
OWER
S
UPPLY
F
ILTERING
C
IRCUIT
Fiber Compatibility
The transceiver is capable of transmission over link distance of 1 meter to
10 km of 9/125 μm fiber, at 125 Mbps Ethernet
or FDDI data rates.
Electrostatic Discharge (ESD)
The Transceiver is compatible with ESD levels found in typical manufacturing and operating environments as described
JEDEC EIA JESD22-A114, Class 1C (<2000Volts) HBM. Glenair recommends that devices are handled with ESD
precautions to limit exposure to below 500V HBM.
There are two design cases in which immunity to ESD damage is important. The first case is during handling of the
transceive
r prior to insertion to the host board. To protect the transceiver, it’s important to use standard industry ESD
handling precautions. These precautions include using grounded wrist straps, work benches, and floor mats in ESD
controlled areas. The ESD sensitivity of the Glenair PCB Mount Transceiver is compatible with typical industry production
environments.
The second case to consider is static discharges to the exterior of the host equipment after installation, in which case the
transceiver may be subject to system-level ESD requirements.