7
Installation and Mounting
The installation must comply with applicable national and local standards, and
CONVECTAIR recommends that it be done by a certified electrician.
This manual was prepared at the time of manufacture of the device and in accordance
with the standards applicable at the time.
The company reserves the right to modify at any time the Installation and User Guide to
account for standards and their evolution.
To avoid short circuits, please turn off the power
at the electrical panel prior to installation or repair.
If the power cable is damaged, it must be replaced by the manufacturer, its after-sales
service personnel or a similarly qualified person to avoid any danger.
If the device has a glass front, do not use if the glass front is damaged.
Convectair recommends an installation height of 15 cm (6 in.).
Minimum
clearances
Front
(A)
Sides
(B)
Above
(C)
Below (E)
Recommended
height
Opera 12
7735
75 cm
(30")
15 cm
(6")
20 cm
(8")
2.5 cm
(1")
15 cm
(6")
Opera 17
7736
75 cm
(30")
15 cm
(6")
20 cm
(8")
2.5 cm
(1")
15 cm
(6")
Opera 46
7737
75 cm
(30")
15 cm
(6")
20 cm
(8")
2.5 cm
(1")
15 cm
(6")
B
15 cm
6 "
C
20 cm
8 "
B
15 cm
6 "
A
75 cm
30 "
E
2,5 cm
1 "
Plancher
Floor
Figure A