8 Do not insert any object in the device.
9 The device must not be installed under a power socket.
10 Minimum installation distances to the floor, walls, furniture, etc., must be respected.
(Figure A). If the device is installed in a bathroom or powder room (Figure B), it must
be installed outside of volume 2 at a minimum distance of 0.5 m from the bathtub and/
or shower and must be fitted with a class A differential circuit breaker.
(IMPORTANT: See applicable national and local codes).
11 If the power cable is damaged, it must be replaced by the manufacturer, its after-sales
service personnel or a similarly qualified person to avoid any danger.
12 Avoid installing the device near a draft that could disrupt its control unit.
13 This direct electric heater is designed to ensure space heating of housing or rooms of
an equivalent type, whether individual or collective, new or existing.
14 Your device is already equipped with a high-precision electronic thermostat. IT
MUST NOT BE CONNECTED TO A WALL MOUNTED THERMOSTAT.
Volume
0
Volume
1
Hors volume
Outside volume
0,5 m
1' 8"
0,5 m
1' 8"
2,25 m * - 7' 5" *
Volume
2
* Hauteur à par�r du fond de la baignoire.
Height from the bo�om of the bath.
Figure B
B
15 cm
6 "
C
20 cm
8 "
B
15 cm
6 "
A
75 cm
30 "
E
2,5 cm
1 "
Plancher
Floor
Figure A